20
–
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1
Reactor
L = 10mH, 16A
2
Outdoor
fan motor
DC140V, 43W
3
Suction temp. sensor (TS sensor)
10k
:
(25°C)
4
Discharge temp. sensor (TD sensor)
62k
:
(20°C)
5
Outside air temp. sensor (TO sensor)
10k
:
(25°C)
6
Heat exchanger temp. sensor (TE sensor)
10k
:
(25°C)
7
Terminal block (6P)
3
0A, AC
600
V
10SAVR-E, 13SAV-E
13SAVR-E, 16SAV-E
, 16SAVR-E
9
COIL FOR P.M.V.
DC12V
10 Coil for 4-way valve
AC220-240V
C12A-01-R
VHV
Compressor
3-phases 4-poles 750W
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA89X1C-23FZ
DA111A1F-20F1
Parts name
Model name
Rating
CH-57
ICF-140-43-4R
11 Compressor thermo
PW-2AL
OFF : 125±4°C, ON : 90±5°C
No.
Fan motor
10SKVR-E,13SKVR-E
(for indoor)
16SKV-E, 16SKVR-E DC 340V, 30W
2
Room temp. sensor (TA-sensor)
10k
Ω
at 25°C
3
Heat exchanger temp. sensor (TC-sensor)
10k
Ω
at 25°C
4
Louver motor
Output (Rated) 1W, 16 poles, DC12V
(
−
)
(
−
)
MP24Z3T
AFS-220-20-4AR AC240V, 20W
Parts name
1
ICF-340-30-2B
Specifications
Type
13SKV-E
MMF-240-20-4B AC240/220V, 20W