3 Tests and Diagnostics
3.2 Executing the Diagnostic Test
PORTEGE M300 Maintenance Manual (960-504)
3-7
Functions 1 through 12 are the Diagnostic Tests. Function 88 sets the floppy disk drive and
hard disk drive error retry count (0-255).
To exit the submenu of the Diagnostic Test and returns to the Diagnostics Menu, set the
highlight bar to function 99 and press
Enter
.
Select the option you want to execute and press
Enter
. When you select
1- SYSTEM TEST
,
the following message will appear:
SYSTEM TEST NAME XXXXXX xxxxxxx DIAGNOSTIC TEST VX.XX
[Ctrl]+[Break] ; test end
[Ctrl]+[C] ;
key stop
SUB-TEST : XX
PASS COUNT : XXXXX
ERROR COUNT : XXXXX
WRITE DATA : XX
READ DATA : XX
ADDRESS : XXXXXX
STATUS : XXX
SUB-TEST MENU :
01 - ROM checksum
02 – Fan ON/OFF
03 - Geyserville
04 - Quick charge
05 - DMI read
99 - Exit to DIAGNOSTIC TEST MENU
NOTE
: The menu displayed by your computer may be slightly different from the one
shown above.
Select the desired subtest number from the subtest menu and press
Enter
. The following message
will appear:
TEST LOOP : YES (or NO)
ERROR STOP : YES (or NO)
Use the right and left arrow keys to move the cursor to the desired option.
Selecting
YES
of TEST LOOP
increases the pass counter by one, each time the test cycle ends
and restarts the test cycle.
Selecting
NO
returns the process to the subtest menu after the test is complete.
Содержание Portege M300
Страница 1: ...Toshiba Personal Computer PORTEGE M300 Maintenance Manual TOSHIBA CORPORATION File Number 960 504 ...
Страница 10: ...x PORTEGE M300 Maintenance Manual 960 504 ...
Страница 43: ...Chapter 2 Troubleshooting Procedures ...
Страница 44: ...2 Troubleshooting Procedures 2 ii PORTEGE M300 Maintenance Manual 960 504 ...
Страница 49: ...2 Troubleshooting Procedures PORTEGE M300 Maintenance Manual 960 504 2 vii ...
Страница 106: ...PORTEGE M300 Maintenance Manual 960 504 3 i Chapter 3 Tests and Diagnostics ...
Страница 107: ...3 ii PORTEGE M300 Maintenance Manual 960 504 ...
Страница 110: ...PORTEGE M300 Maintenance Manual 960 504 3 v 3 32 1 Function Description 3 94 3 32 2 Accessing the SETUP Program 3 96 ...
Страница 112: ...PORTEGE M300 Maintenance Manual 960 504 3 vii ...
Страница 118: ...3 2 Executing the Diagnostic Test 3 Tests and Diagnostics 3 6 PORTEGE M300 Maintenance Manual 960 504 ...
Страница 226: ...3 32 SETUP 3 Tests and Diagnostics 3 110 PORTEGE M300 Maintenance Manual 960 504 ...
Страница 227: ...Chapter 4 Replacement Procedures ...
Страница 228: ...4 Replacement Procedures 4 ii PORTEGE M300 Maintenance Manual 960 504 ...
Страница 232: ...4 Replacement Procedures 4 vi PORTEGE M300 Maintenance Manual 960 504 ...
Страница 313: ...Appendices ...
Страница 314: ...Appendices App ii PORTEGE M300 Maintenance Manual 960 504 ...
Страница 320: ...Appendices App viii PORTEGE M300 Maintenance Manual 960 504 ...
Страница 326: ...Appendix A Handling the LCD Module A 6 PORTEGE M300 Maintenance Manual 960 504 ...
Страница 332: ...B 3 HDD FPC View FNCHD Appendix B Board Layout B 6 PORTEGE M300 Maintenance Manual 960 504 ...
Страница 358: ...C 32 CN9610 HDD I F connector 44 PIN Appendix C Pin Assignment C 26 PORTEGE M300 Maintenance Manual 960 504 ...
Страница 368: ...Appendix E Key Layout E 2 PORTEGE M300 Maintenance Manual 960 504 ...
Страница 370: ...Appendix E Key Layout E 2 PORTEGE M300 Maintenance Manual 960 504 ...
Страница 374: ...Appendix G BIOS Rewrite Procedures G 2 PORTEGE M300 Maintenance Manual 960 504 ...
Страница 376: ...Appendix G BIOS Rewrite Procedures G 2 PORTEGE M300 Maintenance Manual 960 504 ...
Страница 378: ...Appendix H EC KBC Rewrite Procedures H 2 PORTEGE M300 Maintenance Manual 960 504 ...
Страница 380: ...Appendix I Reliability I 2 PORTEGE M300 Maintenance Manual 960 504 ...