iv
3.
Safety Precautions in Daily Use
WARNING
No touch
Do not touch the terminals of the
module and unit during energization.
It may cause an electric shock.
Prohibited
Do not modify, repair, disassemble,
or adjust the device, module, or card.
It may cause an electric shock, fire, injury,
or failure.
Upon faulty operation or failure, contact
Toshiba's branch office or service offices.
Mandatory
Before using, check that the power
capacity, frequency, voltage, and
regulation comply with the device
specifications.
If not, it may cause damage of the
device, or fire due to overheat, as well as
not obtaining the original performance of
the device.
Prohibited
When the ambient or internal
temperature of the device rises
abnormally or failure occurs in the
device, stop using.
Using it as it is may cause fire due to
overheat.
Turn off the power of the device, and
contact one of Toshiba's service
representatives
.
CAUTION
Mandatory
When performing program changes
during operation, forced output, run,
or halt operations, ensure safety.
Wrong operations or failure to ensure
safety may cause an accident or damage
to the machine.
Mandatory
When there is any smoke or strange
odor, turn off the power.
Otherwise, it may cause a fire or electric
shock.
Contact one of our branch offices or
service agencies.
Mandatory
Turn on the power in the following
order:
If this order is not followed, it may cause
an accident or damage to the machine
due to malfunction.
Prohibited
Do not forcefully bend, pull, or twist
the power cord and cables.
It may cause breaks or heating.
Prohibited
Do not insert metal parts or drop a
clip in the clearance of the controller.
It may cause fire.
Mandatory
For system safety, turn off the load
power before the power of the
nv-pack series.
If this order is not followed, it may cause
an accident or damage to the machine.
Share the external power supply for the
I/O module with the load power supply
whenever possible. If this is not
possible, construct the system so that the
external power supply and load power
supply are turned off simultaneously.
Turn on the power of the nv-pack series,
and then turn on the I/O module supply
external power and external load power.
Содержание nv-pack JTLI41
Страница 14: ...6F8C1601 xii ...
Страница 18: ...Chapter 1 Overview 6F8C1601 4 ...
Страница 22: ...Chapter 2 Names and Functions of Parts 6F8C1601 8 ...
Страница 30: ...Chapter 3 Settings 6F8C1601 16 ...
Страница 44: ...Chapter 5 Maintenance and Inspection 6F8C1601 30 ...
Страница 49: ...35 Appendix B Outside Dimensions B 1 JTLI41 36 ...
Страница 51: ...37 Appendix C Related Products ...
Страница 53: ...39 Appendix D Decimal Hex Conversion Table ...
Страница 56: ...Appendix D Decimal Hex Conversion Table 6F8C1601 42 ...
Страница 58: ...1601 1 1703 ...