background image

1

  Precautions for safety

The manufacturer shall not assume any liability for the damage 
caused by not observing the description of this manual.

 WARNING

General

• Carefully read Owner’s Manual before starting the air conditioner. 

There are many important things to keep in mind for daily operation.

• Ask for installation to be performed by the dealer or a professional. 

Only a quali

fi

ed installer (*1) is able to install an air conditioner. If 

a non-quali

fi

ed person installs an air conditioner, it may result in 

problems such as 

fi

re, electric shock, injury, water leakage, noise 

and vibration.

• Do not use any refrigerant different from the one speci

fi

ed for 

complement or replacement. Otherwise, abnormally high pressure 

may be generated in the refrigeration cycle, which may result in a 

failure or explosion of the product or an injury to your body.

• Do not install outdoor units where the operation sound may cause 

a disturbance.

• This appliance is intended to be used by expert or trained users in 

shops, in light industry, or for commercial use by lay persons.

Transportation and storage

• When transporting the air conditioner, wear shoes with protective 

toe caps, protective gloves, and other protective clothing.

• When transporting the air conditioner, do not take hold of the bands 

around the packing carton. You may injure yourself if the bands 

should break.

• When stacking the packing cartons for storage or transportation, 

heed the precautions written on the packing cartons. Failure to heed 

the precautions may cause the stack to collapse.

• You shall ensure that the air conditioner is transported in stable 

condition. If you 

fi

nd any part of the product broken, contact your 

dealer.

Installation

• Only a quali

fi

ed installer(*1) or quali

fi

ed service person(*1) is allowed 

to carry out the electrical work of the air conditioner. Under no 

circumstances must this work be done by an unquali

fi

ed individual 

since failure to carry out the work properly may result in electric 

shocks and/or electrical leaks.

• After the installation work has been completed, have the installer 

explain about the circuit breaker positions. In the event that error 

has occurred in the air conditioner, set the circuit breaker to the OFF 

position, and contact a service person.

• If you install the unit in a small room, take appropriate measures 

to prevent the refrigerant from exceeding the limit concentration 

even if it leaks. Consult the dealer from whom you purchased the 

air conditioner when you implement the measures. Accumulation 

of highly concentrated refrigerant may cause an oxygen de

fi

ciency 

accident.

• Do not install the air conditioner in a location that may be subject to 

a risk of exposure to a combustible gas. If a combustible gas leaks 

and becomes concentrated around the unit, a 

fi

re may occur.

• Be sure to use the company-speci

fi

ed products for the separately 

purchased parts. Use of non-speci

fi

ed products may result in 

fi

re, 

electric shock, water leakage, etc. Have the installation performed 

by a professional.

• Con

fi

rm that earthing is performed correctly.

Operation

• Before opening the intake grille of the indoor unit or service panel of 

the outdoor unit, set the circuit breaker to the OFF position. Failure 

to set the circuit breaker to the OFF position may result in electric 

shocks through contact with the interior parts. Only a quali

fi

ed 

installer(*1) or quali

fi

ed service person(*1) is allowed to remove the 

intake grille of the indoor unit or service panel of the outdoor unit 

and do the work required.

• Inside the air conditioner are high-voltage areas and rotating parts. 

Due to the danger of electric shocks or of your 

fi

ngers or physical 

objects becoming trapped in the rotating parts, do not remove the 

intake grille of the indoor unit or service panel of the outdoor unit. 

When work involving the removal of these parts is required, contact 

a quali

fi

ed installer or a quali

fi

ed service person.

– 3 –

5-EN 

6-EN

Содержание MMY-MUP0801HT8JP-E

Страница 1: ...E MMY MUP1001HT8P E MMY MUP1201HT8P E MMY MUP1401HT8P E MMY MUP1601HT8P E MMY MUP1801HT8P E MMY MUP2001HT8P E MMY MUP2201HT8P E MMY MUP2401HT8P E MMY MUP0801HT8JP E MMY MUP1001HT8JP E MMY MUP1201HT8JP E MMY MUP1401HT8JP E MMY MUP1601HT8JP E MMY MUP1801HT8JP E MMY MUP2001HT8JP E MMY MUP2201HT8JP E MMY MUP2401HT8JP E English ...

Страница 2: ...tters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work The qualified installer who is allowed to work at heights has been trained in matters relating...

Страница 3: ...ould result in slight injury 2 or damage 3 to property if the product is handled improperly 1 Serious bodily harm indicates loss of eyesight injury burns electric shock bone fracture poisoning and other injuries which leave aftereffect and require hospitalization or long term treatment as an outpatient 2 Slight injury indicates injury burns electric shock and other injuries which do not require ho...

Страница 4: ...is work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that error has occurred in the air conditioner set the circuit breaker to the OFF position and contact a service person If you instal...

Страница 5: ...nt Be sure to stop running the air conditioner and turn off the breaker before cleaning Otherwise injury may result as the fan is rotating at high speed inside the unit Repairs When you have noticed that some kind of error such as when an error display has appeared there is a smell of burning abnormal sounds are heard the air conditioner fails to cool or heat or water is leaking has occurred in th...

Страница 6: ...m the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deteriorated after being used for a long time Leaving them such condition may result in the unit s falling down and causing injury Do not leave f...

Страница 7: ... HP For details on these models read the owner s manuals that come with the indoor units Console MML UP NHP For details on these models read the owner s manuals that come with the indoor units Hot Water Module MMW UP LQ For details on these models read the owner s manuals that come with the indoor units 2 Part names Outdoor unit Air discharge Warm air comes out when cooling and cool air when heati...

Страница 8: ...ype MMU UP YHP Air intake grille Air in the room is taken in through here Discharge louver Controls discharge air directions Earth screw Equipped on the electrical control box Air filter Filters out dust Inside the return air grille MMU UP SH Discharge louver Controls discharge air directions Earth screw Equipped on the electrical control box Air intake grille Air in the room is taken in through h...

Страница 9: ... H Discharge louver Controls discharge air directions Earth screw Air intake grille Air in the room is taken in through here Air filter Filters out dust Inside the return air grille Floor Standing Concealed Type MML UP BH Drain funnel with strainer Accessory to be attached at the site Air filter Filters out dust Inside the return air grille Front panel lower Air discharge Earth screw Equipped on t...

Страница 10: ...ral control blinks when the ON OFF MODE or TEMP button on the remote controller is pushed and the buttons do not function Settings that can be configured on the remote controller differ depending on the mode of the central control For details read the Owner s Manual of the central remote controller 3 Setting indicator Indicates that the model is being checked automatically after a breaker is throw...

Страница 11: ...cted Auto cannot be selected at the Fan mode FIX is displayed for models capable of the fan speed setting If you do not push any button for 30s the fan speed mode finishes If you do not push any button for 30s the operation mode finishes 4 Select the temperature Push the setting button to adjust the temperature The temperature setting range is 18 0 C to 29 0 C The temperature can be set in steps o...

Страница 12: ...ooling The louver can be adjusted to four steps Point the louver horizontally If pointing downward dew may form on the surface of the air discharge port and may drop down Initial 1 2 3 4 Swing Operation mode Available directions COOL DRY 1 2 3 4 T For fan The louver can be adjusted to six steps Select a wind direction Auto swing The SWING indicator is displayed and the louver begins swinging Repea...

Страница 13: ...rd in COOL mode water droplets may form on the surface of the cabinet or louver and drop down When the horizontal louver is pointing horizontally in HEAT mode the air may not warm up the room evenly Floor standing type Vertical adjustment T When cooling Move the louver manually and point it horizontally to send cool air across the entire room T When heating Move the louver manually and point it do...

Страница 14: ...areas near oceans etc Hot springs emitting sulfidizing gas etc Heavily acidic or alkaline places e g place disinfection solution is frequently sprayed at Special maintenance or parts are required for use in the above places For details contact the dealer where you purchased the product Leave an enough space around the air intake and discharge of the outdoor unit so that the ventilation is not rest...

Страница 15: ... intake or air discharge of the outdoor unit is blocked When strong wind blows continuously against the air discharge of the outdoor unit During heating When dust or dirt is excessively adhered to the air filter of the indoor unit When the air discharge of the indoor unit is blocked NOTE When the protective device activates turn off the power switch remove the cause and then restart running Coolin...

Страница 16: ... Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the air conditioner may cause dewing Heating operation Outdoor temperature 25 C to 15 5 C Wet bulb temp Room temperature 15 C to 28 C Dry bulb temp If air conditioner is used outside of the above co...

Страница 17: ...deformation or breakage If unused for over a month Leave the fan on for half a day or so to dry the inside Turn off the main power switch Clean the air filter and then attach it Periodic inspection After being used for a long period of time the parts may deteriorate or malfunction or the drainage may worsen due to heat moisture dust or general usage In addition to the maintenance it is recommended...

Страница 18: ...y Is the air intake or air discharge of the outdoor unit obstructed Are any door or window open Is the air filter clogged with dust Is discharge louver of the indoor unit set at appropriate position Is air selection set to Low Med and is the operation mode set to Fan Is the setup temp the appropriate temperature Are Cool and Heat selected simultaneously indication is lit on the display of the remo...

Страница 19: ...EUROPE S A S Route de Thil 01120 Montluel FRANCE Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type MMY MUP0801HT8P E MMY MUP1001HT8P E MMY MUP1201HT8P E MMY MUP1401HT8P E MMY MUP1601HT8P E MMY MUP1801HT8P E MMY MUP2001HT8P E MMY MUP2201HT8P E MMY MUP2401HT8P E MMY MUP0801HT8JP E MMY MUP1001HT8JP E MMY MUP1201HT8JP E MMY MUP1401HT8JP E MMY MUP1601HT8...