  Notes on operations and performance

 

 Check before operation

•  Turn on the power switch at least 12 hours before 

starting operation.

•  Make sure the earth wire is securely connected.
•  Make sure the air 

fi

lter is attached to the indoor unit.

 

 Heating performance

•  A heat pump system, which gathers outside heat and 

emits it into a room, is used for heating. When the 
outside air temperature falls, the heating capacity of 
the unit is reduced.

•  When the outside temperature is low, it is 

recommended that you also use other heating 
equipment.

 

 Defrosting during heating

•  If frost falls on the outdoor unit during heating, 

defrosting is automatically performed 
(for approximately 2 - 10 minutes) to increase the 
heating effect.

•  The fan of the indoor unit is stopped during 

defrosting.

 

 3-minute protection

The outdoor unit will not operate for approximately 
3 minutes after the air conditioner has been 
immediately restarted after stopping, or the power 
switch has been turned on. This is to protect the 
system.

 

 Power failure

•  In the case of a power failure, all operations stop.
•  To resume operations, push the ON / OFF button.

 

 Fan rotation of a stopped 

indoor unit

•  While other indoor units operate, the fans on indoor 

units in stand-by mode rotate for several minutes 
approximately once per one hour to protect the 
machines.

 

 Protective device 

(High pressure switch)

The high pressure switch stops the air conditioner 
automatically when excessive load is applied to the air 
conditioner.
If the protective device activates, the unit’s running 
stops and the operation lamp blinks.
When the protective device activates, the   indicator 
and the check code are displayed on the remote 
controller.
The protective device may activate in the following 
cases:

During cooling

•  When the air intake or air discharge of the outdoor 

unit is blocked.

•  When strong wind blows continuously against the air 

discharge of the outdoor unit.

During heating

•  When dust or dirt is excessively adhered to the air 

fi

lter of the indoor unit.

•  When the air discharge of the indoor unit is blocked.

NOTE

When the protective device activates, turn off the 
power switch, remove the cause, and then restart 
running.

 

 Cooling / Heating operations

Each unit can be controlled individually. However, indoor units connected to the same outdoor unit cannot perform 
cooling and heating simultaneously.
When you attempt simultaneous operation, indoor units performing cooling are stopped, and the running 
preparation indicator   is displayed on the remote controller.
An indoor unit performing heating continues running.
When you attempt an operation without the con

fi

gured settings, the running preparation indicator   is displayed on 

the remote controller and operation stops.
If operation is 

fi

xed to cooling or heating by the air conditioner administrator, only the con

fi

gured settings apply to 

the operation.

 

 Characteristics of heating

•  Air does not come out immediately after heating starts.

Heated air comes out after 3 to 5 minutes (depending on the room / outside temperatures), after the indoor heat 
exchanger warms up.

•  When the outside temperature increases, the outdoor unit may stop.
•  While an indoor unit is running in the heating mode, the outdoor unit supplies refrigerant to the other indoor units 

which are not running. There, noise may come from the other indoor units or the exterior of them may become 
warm.

•  If the Fan operation is performed while the Heat operation is performed in another room, the fan does not run.

 

 Prohibition of NFC function (NFC tag)

NFC communications is enabled at the time of shipping from the factory, but it is possible to disable the test run with 
a smart phone.
Please consult dealer from where you purchased it for more details.

– 14 –

27-EN 

28-EN

Содержание MMY-MUP0801HT8JP-E

Страница 1: ...E MMY MUP1001HT8P E MMY MUP1201HT8P E MMY MUP1401HT8P E MMY MUP1601HT8P E MMY MUP1801HT8P E MMY MUP2001HT8P E MMY MUP2201HT8P E MMY MUP2401HT8P E MMY MUP0801HT8JP E MMY MUP1001HT8JP E MMY MUP1201HT8JP E MMY MUP1401HT8JP E MMY MUP1601HT8JP E MMY MUP1801HT8JP E MMY MUP2001HT8JP E MMY MUP2201HT8JP E MMY MUP2401HT8JP E English ...

Страница 2: ...tters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work The qualified installer who is allowed to work at heights has been trained in matters relating...

Страница 3: ...ould result in slight injury 2 or damage 3 to property if the product is handled improperly 1 Serious bodily harm indicates loss of eyesight injury burns electric shock bone fracture poisoning and other injuries which leave aftereffect and require hospitalization or long term treatment as an outpatient 2 Slight injury indicates injury burns electric shock and other injuries which do not require ho...

Страница 4: ...is work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that error has occurred in the air conditioner set the circuit breaker to the OFF position and contact a service person If you instal...

Страница 5: ...nt Be sure to stop running the air conditioner and turn off the breaker before cleaning Otherwise injury may result as the fan is rotating at high speed inside the unit Repairs When you have noticed that some kind of error such as when an error display has appeared there is a smell of burning abnormal sounds are heard the air conditioner fails to cool or heat or water is leaking has occurred in th...

Страница 6: ...m the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deteriorated after being used for a long time Leaving them such condition may result in the unit s falling down and causing injury Do not leave f...

Страница 7: ... HP For details on these models read the owner s manuals that come with the indoor units Console MML UP NHP For details on these models read the owner s manuals that come with the indoor units Hot Water Module MMW UP LQ For details on these models read the owner s manuals that come with the indoor units 2 Part names Outdoor unit Air discharge Warm air comes out when cooling and cool air when heati...

Страница 8: ...ype MMU UP YHP Air intake grille Air in the room is taken in through here Discharge louver Controls discharge air directions Earth screw Equipped on the electrical control box Air filter Filters out dust Inside the return air grille MMU UP SH Discharge louver Controls discharge air directions Earth screw Equipped on the electrical control box Air intake grille Air in the room is taken in through h...

Страница 9: ... H Discharge louver Controls discharge air directions Earth screw Air intake grille Air in the room is taken in through here Air filter Filters out dust Inside the return air grille Floor Standing Concealed Type MML UP BH Drain funnel with strainer Accessory to be attached at the site Air filter Filters out dust Inside the return air grille Front panel lower Air discharge Earth screw Equipped on t...

Страница 10: ...ral control blinks when the ON OFF MODE or TEMP button on the remote controller is pushed and the buttons do not function Settings that can be configured on the remote controller differ depending on the mode of the central control For details read the Owner s Manual of the central remote controller 3 Setting indicator Indicates that the model is being checked automatically after a breaker is throw...

Страница 11: ...cted Auto cannot be selected at the Fan mode FIX is displayed for models capable of the fan speed setting If you do not push any button for 30s the fan speed mode finishes If you do not push any button for 30s the operation mode finishes 4 Select the temperature Push the setting button to adjust the temperature The temperature setting range is 18 0 C to 29 0 C The temperature can be set in steps o...

Страница 12: ...ooling The louver can be adjusted to four steps Point the louver horizontally If pointing downward dew may form on the surface of the air discharge port and may drop down Initial 1 2 3 4 Swing Operation mode Available directions COOL DRY 1 2 3 4 T For fan The louver can be adjusted to six steps Select a wind direction Auto swing The SWING indicator is displayed and the louver begins swinging Repea...

Страница 13: ...rd in COOL mode water droplets may form on the surface of the cabinet or louver and drop down When the horizontal louver is pointing horizontally in HEAT mode the air may not warm up the room evenly Floor standing type Vertical adjustment T When cooling Move the louver manually and point it horizontally to send cool air across the entire room T When heating Move the louver manually and point it do...

Страница 14: ...areas near oceans etc Hot springs emitting sulfidizing gas etc Heavily acidic or alkaline places e g place disinfection solution is frequently sprayed at Special maintenance or parts are required for use in the above places For details contact the dealer where you purchased the product Leave an enough space around the air intake and discharge of the outdoor unit so that the ventilation is not rest...

Страница 15: ... intake or air discharge of the outdoor unit is blocked When strong wind blows continuously against the air discharge of the outdoor unit During heating When dust or dirt is excessively adhered to the air filter of the indoor unit When the air discharge of the indoor unit is blocked NOTE When the protective device activates turn off the power switch remove the cause and then restart running Coolin...

Страница 16: ... Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the air conditioner may cause dewing Heating operation Outdoor temperature 25 C to 15 5 C Wet bulb temp Room temperature 15 C to 28 C Dry bulb temp If air conditioner is used outside of the above co...

Страница 17: ...deformation or breakage If unused for over a month Leave the fan on for half a day or so to dry the inside Turn off the main power switch Clean the air filter and then attach it Periodic inspection After being used for a long period of time the parts may deteriorate or malfunction or the drainage may worsen due to heat moisture dust or general usage In addition to the maintenance it is recommended...

Страница 18: ...y Is the air intake or air discharge of the outdoor unit obstructed Are any door or window open Is the air filter clogged with dust Is discharge louver of the indoor unit set at appropriate position Is air selection set to Low Med and is the operation mode set to Fan Is the setup temp the appropriate temperature Are Cool and Heat selected simultaneously indication is lit on the display of the remo...

Страница 19: ...EUROPE S A S Route de Thil 01120 Montluel FRANCE Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type MMY MUP0801HT8P E MMY MUP1001HT8P E MMY MUP1201HT8P E MMY MUP1401HT8P E MMY MUP1601HT8P E MMY MUP1801HT8P E MMY MUP2001HT8P E MMY MUP2201HT8P E MMY MUP2401HT8P E MMY MUP0801HT8JP E MMY MUP1001HT8JP E MMY MUP1201HT8JP E MMY MUP1401HT8JP E MMY MUP1601HT8...

Страница 20: ...1141002201 ...

Отзывы: