background image

3

  Part names and functions of the remote 

controller

Remote controller model name : RBC-ASCU11-E

LCD backlight lights for 15 seconds during remote controller operation.
All indicators are displayed in the display example below.
Actually, only the selected options will be displayed.

 

 Operations

1

2

3

4

Operation lamp

Lights during operations.
Blinks when a check occurs or the 
protective device activates.

1

ON/OFF button

Turns on the unit when pushed, and turns off when pushed again.

2

Setting button

Sets setting temperature at the normal mode.
Changes each setting at the Operation mode, the Fan speed mode or the Wind direction mode.

3

OFF timer button

Setting the OFF timer.

4

Menu button

Selects the Operation mode select, the Fan speed select or the Wind direction select.
Each time you push the button, indicator is displayed as followings.
•  The Fan speed select or the Wind direction select is not displayed depending on indoor unit models.

Normal 

operation

mode

Operation 

mode 

select

Fan 

speed 

select

Wind 

direction 

select

 

 Indicators

All icons on the display are shown for this explanation. Operations are not accepted when “SETTING” is 

fl

ashing.

2

3

4

5

6

10

15

11

12

13

7

8

1

9

14

1

Operation mode indicator

Indicates the operation mode selected.

2

Central control indicator

Displayed when the air conditioner is controlled 
centrally and used with central control devices 
such as the central remote controller.
If the use of the remote controller is prohibited by 
the central control, 

 blinks when the ON/OFF, 

MODE, or TEMP. button on the remote controller 
is pushed, and the buttons do not function.
(Settings that can be con

fi

gured on the remote 

controller differ depending on the mode of the 
central control. For details, read the Owner’s 
Manual of the central remote controller.)

3

Setting indicator

Indicates that the model is being checked 
automatically after a breaker is thrown or some 
other occurrence.

4

Service indicator

Displayed while the protective device works or a 
check occurs.

5

Test run indicator

Displayed during test run.

6

Temperature setting indicator

The selected set temperature is displayed.

7

Swing indicator

Displayed during up/down movement of the 
louver.

8

Louver position indicator

Indicates the louver position.

9

Louver lock indicator

Displayed when there is a louver-locked unit.
(4-way cassette type and Compact 4-way 
cassette Type only.)

10

Fan speed indicator

Indicates the selected fan speed

Auto
Low

Low +

Med.

Med. +

High
Fix

11

OFF timer indicator

When a trouble occurs, a check code is 
displayed.

12

Pre-heat indicator

Displayed when the heating mode is energized 
or defrost cycle is initiated.
While this indication is displayed, the indoor fan 
stops or operate in fan mode.

13

Operation standby indicator

Indicates that the Super Modular Multi System 
cannot cool if a different indoor unit is heating 
or cannot heat if one is cooling; and that the 
Super Heat Recovery Multi cannot heat or cool 
because the outside temperature is outside the 
operating range.

14

Remote controller sensor indicator

Displayed while the sensor of the remote 
controller is used.

15

Notice display

Displayed while notice code occurs.

– 9 –

17-EN 

18-EN

Содержание MMY-MUP0801HT8JP-E

Страница 1: ...E MMY MUP1001HT8P E MMY MUP1201HT8P E MMY MUP1401HT8P E MMY MUP1601HT8P E MMY MUP1801HT8P E MMY MUP2001HT8P E MMY MUP2201HT8P E MMY MUP2401HT8P E MMY MUP0801HT8JP E MMY MUP1001HT8JP E MMY MUP1201HT8JP E MMY MUP1401HT8JP E MMY MUP1601HT8JP E MMY MUP1801HT8JP E MMY MUP2001HT8JP E MMY MUP2201HT8JP E MMY MUP2401HT8JP E English ...

Страница 2: ...tters relating to refrigerant handling and piping work on the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such matters by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to this work The qualified installer who is allowed to work at heights has been trained in matters relating...

Страница 3: ...ould result in slight injury 2 or damage 3 to property if the product is handled improperly 1 Serious bodily harm indicates loss of eyesight injury burns electric shock bone fracture poisoning and other injuries which leave aftereffect and require hospitalization or long term treatment as an outpatient 2 Slight injury indicates injury burns electric shock and other injuries which do not require ho...

Страница 4: ...is work be done by an unqualified individual since failure to carry out the work properly may result in electric shocks and or electrical leaks After the installation work has been completed have the installer explain about the circuit breaker positions In the event that error has occurred in the air conditioner set the circuit breaker to the OFF position and contact a service person If you instal...

Страница 5: ...nt Be sure to stop running the air conditioner and turn off the breaker before cleaning Otherwise injury may result as the fan is rotating at high speed inside the unit Repairs When you have noticed that some kind of error such as when an error display has appeared there is a smell of burning abnormal sounds are heard the air conditioner fails to cool or heat or water is leaking has occurred in th...

Страница 6: ...m the unit Prevent any liquid from falling into the remote controller Do not spill juice water or any kind of liquid Do not wash the air conditioner Doing so may result in electric shock Check whether the installation base and other equipment have become deteriorated after being used for a long time Leaving them such condition may result in the unit s falling down and causing injury Do not leave f...

Страница 7: ... HP For details on these models read the owner s manuals that come with the indoor units Console MML UP NHP For details on these models read the owner s manuals that come with the indoor units Hot Water Module MMW UP LQ For details on these models read the owner s manuals that come with the indoor units 2 Part names Outdoor unit Air discharge Warm air comes out when cooling and cool air when heati...

Страница 8: ...ype MMU UP YHP Air intake grille Air in the room is taken in through here Discharge louver Controls discharge air directions Earth screw Equipped on the electrical control box Air filter Filters out dust Inside the return air grille MMU UP SH Discharge louver Controls discharge air directions Earth screw Equipped on the electrical control box Air intake grille Air in the room is taken in through h...

Страница 9: ... H Discharge louver Controls discharge air directions Earth screw Air intake grille Air in the room is taken in through here Air filter Filters out dust Inside the return air grille Floor Standing Concealed Type MML UP BH Drain funnel with strainer Accessory to be attached at the site Air filter Filters out dust Inside the return air grille Front panel lower Air discharge Earth screw Equipped on t...

Страница 10: ...ral control blinks when the ON OFF MODE or TEMP button on the remote controller is pushed and the buttons do not function Settings that can be configured on the remote controller differ depending on the mode of the central control For details read the Owner s Manual of the central remote controller 3 Setting indicator Indicates that the model is being checked automatically after a breaker is throw...

Страница 11: ...cted Auto cannot be selected at the Fan mode FIX is displayed for models capable of the fan speed setting If you do not push any button for 30s the fan speed mode finishes If you do not push any button for 30s the operation mode finishes 4 Select the temperature Push the setting button to adjust the temperature The temperature setting range is 18 0 C to 29 0 C The temperature can be set in steps o...

Страница 12: ...ooling The louver can be adjusted to four steps Point the louver horizontally If pointing downward dew may form on the surface of the air discharge port and may drop down Initial 1 2 3 4 Swing Operation mode Available directions COOL DRY 1 2 3 4 T For fan The louver can be adjusted to six steps Select a wind direction Auto swing The SWING indicator is displayed and the louver begins swinging Repea...

Страница 13: ...rd in COOL mode water droplets may form on the surface of the cabinet or louver and drop down When the horizontal louver is pointing horizontally in HEAT mode the air may not warm up the room evenly Floor standing type Vertical adjustment T When cooling Move the louver manually and point it horizontally to send cool air across the entire room T When heating Move the louver manually and point it do...

Страница 14: ...areas near oceans etc Hot springs emitting sulfidizing gas etc Heavily acidic or alkaline places e g place disinfection solution is frequently sprayed at Special maintenance or parts are required for use in the above places For details contact the dealer where you purchased the product Leave an enough space around the air intake and discharge of the outdoor unit so that the ventilation is not rest...

Страница 15: ... intake or air discharge of the outdoor unit is blocked When strong wind blows continuously against the air discharge of the outdoor unit During heating When dust or dirt is excessively adhered to the air filter of the indoor unit When the air discharge of the indoor unit is blocked NOTE When the protective device activates turn off the power switch remove the cause and then restart running Coolin...

Страница 16: ... Dry bulb temp Room temperature 21 C to 32 C Dry bulb temp 15 C to 24 C Wet bulb temp CAUTION Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the air conditioner may cause dewing Heating operation Outdoor temperature 25 C to 15 5 C Wet bulb temp Room temperature 15 C to 28 C Dry bulb temp If air conditioner is used outside of the above co...

Страница 17: ...deformation or breakage If unused for over a month Leave the fan on for half a day or so to dry the inside Turn off the main power switch Clean the air filter and then attach it Periodic inspection After being used for a long period of time the parts may deteriorate or malfunction or the drainage may worsen due to heat moisture dust or general usage In addition to the maintenance it is recommended...

Страница 18: ...y Is the air intake or air discharge of the outdoor unit obstructed Are any door or window open Is the air filter clogged with dust Is discharge louver of the indoor unit set at appropriate position Is air selection set to Low Med and is the operation mode set to Fan Is the setup temp the appropriate temperature Are Cool and Heat selected simultaneously indication is lit on the display of the remo...

Страница 19: ...EUROPE S A S Route de Thil 01120 Montluel FRANCE Hereby declares that the machinery described below Generic Denomination Air Conditioner Model type MMY MUP0801HT8P E MMY MUP1001HT8P E MMY MUP1201HT8P E MMY MUP1401HT8P E MMY MUP1601HT8P E MMY MUP1801HT8P E MMY MUP2001HT8P E MMY MUP2201HT8P E MMY MUP2401HT8P E MMY MUP0801HT8JP E MMY MUP1001HT8JP E MMY MUP1201HT8JP E MMY MUP1401HT8JP E MMY MUP1601HT8...

Страница 20: ...1141002201 ...