![Toshiba MMC-P0151H Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/toshiba/mmc-p0151h/mmc-p0151h_design-manual_423774028.webp)
1-26
NOTE :
RLA is based on the following conditions.
Indoor temperature : 27°C DB/19°C WB
Outdoor temperature
: 35°C DB
n
Single outdoor unit
NOTE : A fixed-speed unit cannot be used for a single outdoor unit. It is necessarily used together with an inverter unit.
n
Combination of outdoor unit
Legend
MCA : Minimum Circuit Amps
MOCP : Maximum Overcurrent Protection (Amps)
ICF
: Maximum Instantaneous Current Flow Start
RLA
: Rated Load Amps
LRA
: Locked Rotor Amps
FLA
: Full Load Amps
kW
: Fan Motor Rated Output (kW)
50Hz
Cooling
only Model
MMY-
P1401T8
P1601T8
P1801T8
P2001T8
P2201T8
P2401T8
P2601T8
P2801T8
P3001T8
P3201T8
P3401T8
P3601T8
P3801T8
P4001T8
P4201T8
P4401T8
P4601T8
Heat Pump
Model
MMY-
P1401HT8
P1601HT8
P1801HT8
P2001HT8
P2201HT8
P2401HT8
P2601HT8
P2801HT8
P3001HT8
P3201HT8
P3401HT8
P3601HT8
P3801HT8
P4001HT8
P4201HT8
P4401HT8
P4601HT8
Nominal
Voltage
(V-Ph-Hz)
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
Voltage Range
Min
Max
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
342
457
Compressor
No.1
RLA
LRA
11.0+11.0 65
11.0+11.0 65
12.7+12.7 65
12.7+12.7 65
11.0+11.0 65
11.0+11.0 65
12.7+12.7 65
12.7+12.7 65
12.7+12.7 65
11.0+11.0 65
12.7+12.7 65
12.7+12.7 65
12.7+12.7 65
12.7+12.7 65
12.7+12.7 65
12.7+12.7 65
12.7+12.7 65
No.2
RLA
LRA
12.7
65
11.0+11.0 65
11.0+11.0 65
12.7+12.7 65
11.0+11.0 65
11.0+11.0 65
11.0+11.0 65
12.7+12.7 65
12.7+12.7 65
11.0+11.0 65
11.0+11.0 65
12.7+12.7 65
12.7+12.7 65
12.7+12.7 65
11.0+11.0 65
12.7+12.7 65
12.7+12.7 65
No.3
RLA
LRA
—
—
—
—
—
—
—
—
12.7
65
11.0+11.0 65
11.0+11.0 65
11.0+11.0 65
12.7+12.7 65
11.0+11.0 65
11.0+11.0 65
11.0+11.0 65
12.7+12.7 65
12.7+12.7 65
11.0+11.0 65
11.0+11.0 65
12.7+12.7 65
No.4
RLA
LRA
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
11.0+11.0 65
11.0+11.0 65
11.0+11.0 65
11.0+11.0 65
12.7+12.7 65
11.0+11.0 65
11.0+11.0 65
11.0+11.0 65
No.5
RLA
LRA
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
11.0+11.0
65
11.0+11.0
65
11.0+11.0
65
Fan Motor
kW
FLA
0.35×2
5.6
0.35×2
5.6
0.35×2
5.6
0.35×2
5.6
0.35×3
8.4
0.35×3
8.4
0.35×3
8.4
0.35×3
8.4
0.35×3
8.4
0.35×4
11.2
0.35×4
11.2
0.35×4
11.2
0.35×4
11.2
0.35×4
11.2
0.35×5
14.0
0.35×5
14.0
0.35×5
14.0
Power Supply
MCA MOCP
ICF
43.5
60
93
52.4
70
104
56.2
70
105
59.6
80
109
68.3
90
117
77.2
100
128
81.0
100
130
84.4
110
134
87.8
110
137
102.0
130
153
105.8
130
155
109.2
150
158
112.6
150
162
116.0
150
165
130.6
170
180
134.0
170
183
137.4
170
187
Cooling only
Model MMY-
MP0801T8
MP1001T8
MP06018
MP08018
MP10018
Heat Pump Model
MMY-
MP0801HT8
MP1001HT8
MP0601H8
MP0801H8
MP1001H8
Nominal Voltage
(V-Ph-Hz)
400-3-50
400-3-50
400-3-50
400-3-50
400-3-50
Voltage Range
Min
Max
342
457
342
457
342
457
342
457
342
457
Compressor
RLA
LRA
11.0+11.0
65
12.7+12.7
65
12.7
65
11.0+11.0
65
12.7+12.7
65
Fan Motor
kW
FLA
0.35
2.8
0.35
2.8
0.35
2.8
0.35
2.8
0.35
2.8
Power Supply
MCA
MOCP
ICF
27.6
35
79
31.4
40
81
18.7
30
68
27.6
35
79
31.4
40
81
Type
Inv. unit
Fixed-speed unit