Ye
s
No
Ye
s
No
[F03]
Ye
s
No
Ye
s
No
[F01]
Ye
s
No
Ye
s
No
[F02]
[F04]
[F05]
e
s
u
a
C
e
d
o
c
k
c
e
h
C
Check code name
e
s
u
a
C
e
d
o
c
k
c
e
h
C
Check code name
e
s
u
a
C
e
d
o
c
k
c
e
h
C
Check code name
e
s
u
a
C
e
d
o
c
k
c
e
h
C
Check code name
e
s
u
a
C
e
d
o
c
k
c
e
h
C
Check code name
Indoor
TCJ sensor error
TCJ sensor Open/Short
Indoor
TC1 sensor error
TC1 sensor Open/Short
TD1 sensor error
TD1 sensor Open/Short
TD2 sensor error
TD2 sensor Open/Short
[F06]
e
d
o
c
k
c
e
h
C
Check code name
TE1
,TE2
sensor error
Cause
TE1
,TE2
sensor Open/Short
Indoor TC2
sensor
error
TC2 sensor Open/Short
Is TCJ
sensor connector
(CN102: Red) on indoor
P
.C. board normally
connected?
Is TC1
sensor connector
(CN100: Brown) on indoor
P
.C. board normally
connected?
Are characteristics
of
TCJ sensor resistance
value normal?
Are characteristics
of TC1
sensor
resistance
value normal?
Is TC2
sensor connector
(CN101: Black) on indoor
P
.C. board normally
connected?
Are characteristics of
TC2 sensor resistance
value normal?
Correct connection of
connector
.
Correct connection of
connector
.
Replace TC1
sensor
.
Replace TCJ
sensor
.
Correct connection of
connector
.
Replace TC2
sensor
.
Check indoor P
.C. board.
Defect
Replace
Check indoor main P
.C. board.
Defect
Replace
Check indoor P
.C. board.
Defect
Replace
*
See
“
Indoo
r
uni
t
temperature
sen
sor characteri
stics” on
“8-
10
. Sensor Characteristics”.
*
See
“
Indoo
r unit
temperature
sen
sor characteri
stics” on
“8-
10
. Sensor Characteristics”.
* See
“I
ndoor unit temperature
sen
sor characteristics”
o
n
“8
-
10
. Senso
r
Characteristics”.
This e
rro
r co
de
mea
n
s d
e
te
ction
of
Ope
n/S
ho
rt
of
TD1
se
nsor.
Ch
eck d
iscon
nec
tion
of circuit
for co
nn
ectio
n o
f
connector
(
TD1
sen
sor: CN502, White) and characteristics of
sensor
resistance value. (See “Outdoor unit
tempe
rature
sensor characteristics” on
“8
-
10
. Sensor
Characteristics”.)
If se
nso
r
is no
rm
a
l,
re
pla
ce o
utd
oo
r
I/F P.
C.
bo
ar
d.
This e
rro
r co
de
mea
n
s d
e
te
ction
of
Ope
n/S
ho
rt
of
TD
2
se
nsor.
Ch
eck d
iscon
nec
tion
of circuit
for co
nn
ectio
n o
f
connector (TD2
sen
sor: CN503, Pink) and characteristic
s
of sensor resistance value.
(S
ee “Outdoor unit
tempe
rature
sensor characteristics” on
“8
-
10
. Sensor
Characteristics”.)
If se
nso
r
is no
rm
a
l,
re
pla
ce o
utd
oo
r
I/F P.
C.
bo
ar
d.
This error code
mea
ns detection
of
Open/Short
of TE1
sensor. Check disconnection
o
f
circuit for conne
ction
of
connector (TE1 sensor:
CN520,G
r
een,
TE2
sensor
: CN521,
Red
) and characteristics of
sensor resistance
value.
(See “O
utdoor unit temperature
sensor characteristics” on
“8
-
10
. Sensor
Characteristics”.)
If se
nso
r
is no
rm
a
l,
re
pla
ce o
utd
oo
r
I/F P.
C.
bo
ar
d.
−
1
93
−
AMP Air Conditioning
www.ampair.co.uk | [email protected]
Содержание MAP1406HT8(J)P
Страница 304: ...For HT8 J P E HT8 J P TR model 303 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 305: ...For T8 J P T7 J P T8P SG T8 J P ID T8 J P T model 304 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 311: ... 310 For HT8 J P E HT8 J P TR model AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 312: ... 311 For T8 J P T7 J P T8P SG T8 J P ID T8 J P T model AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 318: ... 317 For HT8 J P E HT8 J P TR model AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 319: ... 318 For T8 J P T7 J P T8P SG T8 J P ID T8 J P T model AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 345: ...AMP Air Conditioning www ampair co uk sales ampair co uk ...