6F8A0917
- 71 -
Checking the unit string of custom unit
Proceed as follows to check the unit string of custom unit.
Switch operation
Display example
Description
B4: CUSTOM UNIT
AAA/BBB
Select B4: CUSTOM DATA from the setting item selection
menu.
The currently set unit appears.
B4: CUSTOM UNIT
Returns to the menu of setting item selection.
Changing the unit string of custom unit
The following is an example to show how to change the unit string from AAA/BBB to XXX/ZZZ.
Switch operation
Display example
Description
B4: CUSTOM UNIT
AAA/BBB
Select B4: CUSTOM UNIT from the setting item selection
menu.
The currently set unit appears.
B4: CUSTOM UNIT
AAA/BBB
The cursor appears.
Press
further to move the cursor to the desired digit to
change.
B4: CUSTOM UNIT
XAA/BBB
↓
XXX/ZZZ
Change the character of the digit. (Note 1)
To change other digit, press
to move the cursor to that digit
and change the character there. Repeat this operation until
XXX/ZZZ appears on the display.
B4: CUSTOM UNIT
XXX/ZZZ
The display blinks and the set value is displayed for
confirmation.
Press
MENU/ENT
again to write the data. Then the cursor
disappears and the display returns to the condition that the set
value is displayed.
B4: CUSTOM UNIT
Returns to the menu of setting item selection.
Note 1: The selectable characters are displayed cyclically as shown below:
Alphabet letter (lowercase)
Alphabet letter (uppercase)
Symbol
Number