GX9 ASD Installation and Operation Manual
13
Load-Produced Negative Torque
When the
GX9 ASD
is used with a load that produces negative torque (an overhauling load), the over-
voltage or over-current protective functions of the GX9 ASD may cause nuisance tripping.
To minimize the undesirable effects of negative torque the dynamic braking system may be used if so
equipped. The dynamic braking system converts the regenerated energy into heat that is dissipated using a
braking resistor. The braking resistor must be suitably matched to the load. Dynamic braking is also
effective in reducing the DC bus voltage during a momentary over-voltage condition.
If under extreme conditions the dynamic braking system or a component of this system were to fail, the
dynamic braking resistor may experience an extended over-current condition. The DBR circuit was
designed to dissipate excessive amounts of heat and if the extended over-current condition were allowed
to exceed the circuit parameters, this condition could result in a fire hazard.
To combat this condition, the 3-phase input may be connected using contactors that are configured to open
in the event of an extended DBR over-current condition or an internal circuit failure. Using a thermal
sensor and/or overload protection as the 3-phase input contactor drive signal, the contactors will open and
remove the 3-phase input power in the event of an extended DBR over-current or system over-voltage
condition.
Motor Braking
The motor may continue to rotate and coast to a stop after being shut off due to the inertia of the load. If an
immediate stop is required, a braking system should be used. The two most common types of motor
braking systems used with the
GX9 ASD
are
DC Injection Braking
and
Dynamic Braking
.
For further information on braking systems, see
DC Injection Braking on pg. 124
and
.
CAUTION
Содержание GX9
Страница 1: ...GX9 ASD Install Op Manual TOSHIBA GX9 ASD INSTALLATION OPERATION MANUAL DN 66893 001 March 2014 ...
Страница 2: ......
Страница 3: ...Document Number 66893 001 March 2014 GX9 ASD Installation Operation Manual ...
Страница 4: ......
Страница 12: ...iv GX9 ASD Installation and Operation Manual ...
Страница 251: ...GX9 ASD Installation and Operation Manual 239 Figure 36 GX9 ASD 5 0 20 HP Enclosure ...
Страница 252: ...240 GX9 ASD Installation and Operation Manual Figure 37 GX9 ASD 25 75 HP Enclosure ...
Страница 253: ...GX9 ASD Installation and Operation Manual 241 Figure 38 GX9 ASD 100 200 HP Enclosure ...
Страница 254: ...242 GX9 ASD Installation and Operation Manual Figure 39 GX9 ASD 250 400 HP Enclosure ...
Страница 255: ...GX9 ASD Installation and Operation Manual 243 Figure 40 GX9 ASD 500 800 HP Enclosure ...
Страница 256: ...244 GX9 ASD Installation and Operation Manual Figure 41 GX9 ASD 900 1200 HP Enclosure ...
Страница 268: ......
Страница 269: ......