122
GX9 ASD Installation and Operation Manual
PG Reference Point 1
Program
Frequency
Speed Reference Setpoints
This parameter is used to set the gain and bias of the
PG
input of the option
board when a shaft-mounted encoder is used as the control input while
operating in the
Speed Control
mode.
Note:
See Instruction Manual D/N 58687 for more information on the
PG Option Board
.
PG Speed Control Setup
Perform the following setup to allow the system to receive
Speed
control input
at the
PG
input:
• Program
Fundamental
Standard Mode Selection
Frequency Mode
1
Pulse Input
(option).
• Program
Fundamental
Standard Mode Selection
Command Mode
Selection
(Application-Specific).
• Set
PG Input Point 1 Frequency
(
• Set the
PG
input value (
) that represents
PG Reference Point 1
.
• Set
PG Input Point 2 Frequency
(
• Set the
PG
input value (
) that represents
PG Reference Point 2
.
• Provide a
Run
command (F and/or R).
Once set, as the
PG
input pulse count rate changes, the output frequency of the
ASD will vary in accordance with the above settings.
This parameter sets the
PG
input pulse count that represents
Reference
Setpoint 1
(frequency). The range of values for this parameter is -100% to
100% of the
PG
input pulse count range.
Note:
Further application-specific
PG
settings may be performed from
the following path: Program
Feedback
PG Settings
Direct Access Number — F234
Parameter Type —
Numerical
Factory Default —
0.0
Changeable During Run —
Yes
Minimum — -100.00
Maximum — +100.00
Units — %
Frequency Settings
PG Input Point 1 Frequency
Program
Frequency
Speed Reference Setpoints
This parameter is used to set the speed of the
PG
input when the
PG
input is
used as the control input.
This parameter sets
PG Input Point 1 Frequency
and is the frequency that is
associated with the setting of
PG Reference Point 1
.
See
PG Reference Point 1
)
for further information on this setting.
Direct Access Number — F235
Parameter Type —
Numerical
Factory Default —
0.0
Changeable During Run —
Yes
Minimum — -
Max. Freq.
(
Maximum —
Max. Freq.
Units — Hz
PG Reference Point 2
Program
Frequency
Speed Reference Setpoints
This parameter is used to set the direction and speed of the
PG
input when the
PG
input is used as the control input.
This parameter sets the
PG
input signal that is associated with
PG Input Point
2 Frequency
.
This value is entered as -100% to +100% of the
PG
input signal range.
See
PG Reference Point 1
) for further information on this setting.
Direct Access Number — F236
Parameter Type —
Numerical
Factory Default —
100.00
Changeable During Run —
Yes
Minimum — -100.00
Maximum — +100.00
Units — %
Содержание GX9
Страница 1: ...GX9 ASD Install Op Manual TOSHIBA GX9 ASD INSTALLATION OPERATION MANUAL DN 66893 001 March 2014 ...
Страница 2: ......
Страница 3: ...Document Number 66893 001 March 2014 GX9 ASD Installation Operation Manual ...
Страница 4: ......
Страница 12: ...iv GX9 ASD Installation and Operation Manual ...
Страница 251: ...GX9 ASD Installation and Operation Manual 239 Figure 36 GX9 ASD 5 0 20 HP Enclosure ...
Страница 252: ...240 GX9 ASD Installation and Operation Manual Figure 37 GX9 ASD 25 75 HP Enclosure ...
Страница 253: ...GX9 ASD Installation and Operation Manual 241 Figure 38 GX9 ASD 100 200 HP Enclosure ...
Страница 254: ...242 GX9 ASD Installation and Operation Manual Figure 39 GX9 ASD 250 400 HP Enclosure ...
Страница 255: ...GX9 ASD Installation and Operation Manual 243 Figure 40 GX9 ASD 500 800 HP Enclosure ...
Страница 256: ...244 GX9 ASD Installation and Operation Manual Figure 41 GX9 ASD 900 1200 HP Enclosure ...
Страница 268: ......
Страница 269: ......