PWM Carrier Frequency
Program
Special
Carrier Frequency
This parameter sets the frequency of the pulse width modulation signal applied
to the motor.
Note:
When operating in the
Vector Control
mode the carrier
frequency should be set to 2.2 kHz or above
.
Note:
If the PWM carrier frequency is set at 2.0 kHz or above, it cannot
be decreased below 2.0 kHz while running. If the PWM carrier
frequency is set at 1.9 kHz or below, it cannot be increased above
2.0 kHz while running. Either change requires that the ASD be
stopped and restarted for the changes to take effect.
Direct Access Number — F300
Parameter Type —
Numerical
Factory Default —
2.200
Changeable During Run —
No
Minimum — 0.500
Maximum —
(ASD-Dependent)
Units — kHz
Auto Restart Selection
Program
Protection
Retry/Restart
This parameter
Enables/Disables
the ability of the ASD to start into a spinning
motor when the
ST
–
CC
connection opens momentarily and is then closed
(Break/Make ST) or after a power interruption (momentary power failure).
See F312 for more on this parameter setting.
Settings:
0 — Off
1 — Power Failure
2 — Make/Break ST
3 — Make/Break ST or Power Failure
Direct Access Number — F301
Parameter Type —
Selection List
Factory Default —
Off
Changeable During Run —
Yes
Regenerative Power Ridethrough Selection
Program
Protection
Under-Voltage/Ridethrough
This parameter determines the motor control response of the ASD in the event
of a momentary power outage, under-voltage condition, or an
selection
(1–3) event.
During a
Ridethrough
, regenerative energy is used to maintain the control
circuitry settings for the duration of the
Ridethrough
; it is not used to drive the
motor. The motor(s) of the system are stopped and then restarted automatically
if so configured.
Note:
If used to restart the motor, the Retry setup of
is required.
Settings:
0 — Off
1 — Ridethrough
2 — Deceleration Stop
Direct Access Number — F302
Parameter Type —
Selection List
Factory Default —
Off
Changeable During Run —
Yes
Содержание GX9
Страница 1: ...GX9 ASD Install Op Manual TOSHIBA GX9 ASD INSTALLATION OPERATION MANUAL DN 66893 001 March 2014 ...
Страница 2: ......
Страница 3: ...Document Number 66893 001 March 2014 GX9 ASD Installation Operation Manual ...
Страница 4: ......
Страница 12: ...iv GX9 ASD Installation and Operation Manual ...
Страница 251: ...GX9 ASD Installation and Operation Manual 239 Figure 36 GX9 ASD 5 0 20 HP Enclosure ...
Страница 252: ...240 GX9 ASD Installation and Operation Manual Figure 37 GX9 ASD 25 75 HP Enclosure ...
Страница 253: ...GX9 ASD Installation and Operation Manual 241 Figure 38 GX9 ASD 100 200 HP Enclosure ...
Страница 254: ...242 GX9 ASD Installation and Operation Manual Figure 39 GX9 ASD 250 400 HP Enclosure ...
Страница 255: ...GX9 ASD Installation and Operation Manual 243 Figure 40 GX9 ASD 500 800 HP Enclosure ...
Страница 256: ...244 GX9 ASD Installation and Operation Manual Figure 41 GX9 ASD 900 1200 HP Enclosure ...
Страница 268: ......
Страница 269: ......