4.HYDRO UNIT
Engineering Data book
12
4
4. HYDRO UNIT
4-1. Specification
4-1-1. Hydro unit specifications
Hydro unit
HWS-803XWHM3-E HWS-803XWHT6-E HWS-803XWHD6-E HWS-803XWHT9-E
Back up heater
back up heater
kW
3
6
6
9
Power supply
1 ~ 220-230V 50Hz 3N~ 380-400V 50Hz 3~ 220-230V 50Hz 3N~ 380-400V 50Hz
Maximum current
A
13
13 (13A*2P)
23A
13 (13A*3P)
Hot water
cylinder heater*
Power supply
1 ~ 220-230V 50Hz
Maximum current
A
12.0
Appearance
Color
Silky shade (Muncel 1Y8.5-0.5)
Material
PCM
Outer dimension
Height
mm
925
Width
mm
525
Depth
mm
355
Unit weight
kg
50
Packing
dimension
Height
mm
1070
Width
mm
608
Depth
mm
436
Total weight
Unit and packing
kg
54
Heat exchanger
Type
Brazed plate
Water volume
litres
0.67
Minimum flow rate
/min
13
Water pump
Power input
W
125 / 95 / 65
Delivery head
m
6.5 / 6.1 / 4.5
Expansion
vessel
Volume
litres
12
Initial pressure
MPa(bar)
0.1 (1)
Pressure relief
valve
Operating pressure
MPa(bar)
0.3 (3)
Sound pressure level
dBA
29
Operation water
temp.
Heating
°C
20~55
Cooling
°C
10~25
Water pipe
Outlet
mm
34.92
Inlet
mm
34.92
Refrigerant pipe
Gas
mm
15.9
Liquid
mm
9.5
Drain port
mm
16.0 inner diameter for drain hose
Note
* The electric heater, incorporated in the hot water cylinder, requires separete supply
to hydro unit.
Содержание ESTIA HWS-1501CSHM3-E
Страница 3: ...2 1 INTRODUCTION ...
Страница 7: ...6 2 SYSTEM OVERVIEW ...
Страница 11: ...10 3 SYSTEM SPECIFICATION ...
Страница 60: ...59 5 OUTDOOR UNIT ...
Страница 79: ...78 6 HOT WATER CYLINDER ...
Страница 85: ...84 7 HYDRO UNIT INSTALLATION MANUAL ...
Страница 132: ... 131 7 HYDRO UNIT INSTALLATION MANUAL Engineering Data Book MEMO ...
Страница 133: ...132 8 OUTDOOR UNIT INSTALLATION MANUAL ...
Страница 162: ... 161 8 OUTDOOR UNIT INSTALLATION MANUAL Engineering Data book MEMO ...
Страница 163: ...162 9 OWNER S MANUAL ...
Страница 179: ...Air to Water Heat Pump Engineering Data Book Oct 2010 ...