PREVENTIVE MAINTENANCE (PM)
5 - 16
5.6
Fuser Unit Status Detection Mode
5.6.1
General description
As this equipment complies with the ERU provisions (Easy Replacement Unit), the fuser unit can be
removed or reinstalled without any problem.
The fuse (service part) for detection of a new fuser unit can be installed in the unit. The circuit
determining the fuser unit status judges whether the fuser unit is new or used by detecting the status of
the fuse. In addition, when the circuit detects that a new fuser unit is connected, it supplies current to
blow out the fuse to clear the fuser-related life counters.
Note:
If only the supply parts in the fuser unit are to be replaced at PM, perform life counter clearing for
each one in the PM support mode as described in this chapter.
5.6.2
Operational flow
(1) When replacing supply parts or the fuser unit at PM, install a new fuse in it.
Note:
If a fuser unit with an installed fuse is selected, replace that the fuse with a new one because it
will have been blown out.
(2) Install the fuser unit in the equipment.
(3) Turn the power ON. If the fuser unit is then judged determined to be new, the fuser-related life
counters are automatically cleared.
5.6.3
Counters to be cleared
• 08-1246: Fuser roller counter
• 08-1250: Pressure roller counter
• 08-1268: Fuser roller separation finger counter
• 08-1372: Heater and energizing time accumulating counter
• 08-1378: Counter for period of time fuser unit is at ready temperature
• 08-1380: Counter for period of time fuser unit is at printing temperature
• 08-1382: Counter for period of time fuser unit is at energy saving temperature
• 08-1385: Number of output pages (Thick paper 1)
• 08-1386: Number of output pages (Thick paper 2)
• 08-1387: Number of output pages (Thick paper 3)
• 08-1388: Number of output pages (OHP film)
• 08-1411: Counter for envelopes
• 08-1412: Counter for tab paper
5.6.4
Precautions
• When the counters are not cleared, though the fuser unit is new, check that the value of the code
08-4549 is set at "0". If the value is "1", change it to "0", turn the power OFF and then back ON.
Then check the counter values again.
08-4549 (Detection setting of new or old fuser unit) 0: Enabled, 1: Disabled
• When the fuse is not blown out, though the fuser unit is new, a C4C0 error occurs. In this case,
replace the fuse and turn the power OFF and then back ON, or remove the fuse and clear the
counters in the PM support mode.
Содержание e-studio205L
Страница 6: ......
Страница 10: ......
Страница 336: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 96 ...
Страница 354: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 4 18 ...
Страница 404: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 5 50 ...
Страница 576: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 14 Engine ROM Fig 8 8 ...
Страница 626: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 9 10 ...
Страница 664: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 11 2 ...
Страница 670: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved REVISION RECORD 2 ...
Страница 671: ......
Страница 672: ......