e-STUDIO205L/255/305/355/455
© 2009 TOSHIBA TEC CORPORATION All rights reserved
SELF-DIAGNOSIS MODES
2 - 130
1396
Paper
feeding
Feeding retry counter
upper limit value
(Upper drawer)
ALL
0
<8 digits>
M
When the number of
feeding retry (08-1390
to 08-1395) exceeds
the setting value, the
feeding retry will not be
performed
subsequently. In case
“0” is set as a setting
value, however, the
feeding retry continues
regardless of the
counter setting value.
1
1397
Paper
feeding
Feeding retry counter
upper limit value
(Lower drawer)
ALL
0
<8 digits>
M
1
1398
Paper
feeding
Feeding retry counter
upper limit value
(PFP upper drawer)
ALL
0
<8 digits>
M
1
1399
Paper
feeding
Feeding retry counter
upper limit value
(PFP lower drawer)
ALL
0
<8 digits>
M
1
1400
Paper
feeding
Feeding retry counter
upper limit value
(Bypass feed)
ALL
0
<8 digits>
M
1
1401
Paper
feeding
Feeding retry counter
upper limit value
(Tandem LCF)
ALL
0
<8 digits>
M
1
1410
Counter
Counter for toner
cartridge rotation time
ALL
0
<8 digits>
M
Counts up the period of
rotation time of the
toner cartridge.
The counter value is
based on the data of
toner cartridge.
1
1411
Counter
Counter for envelope
ALL
0
<8 digits>
M
Counts up when the
registration sensor is
ON.
When the counter value
of the fuser roller is
reset, this counter is
reset in sync at the PM
support mode.
1
1412
Counter
Counter for tab paper
ALL
0
<8 digits>
M
Counts up when the
registration sensor is
ON in the tab paper
mode.
1
1422
Data
overwrite
option
HDD data overwriting
type setting
ALL
0
<0-2>
SYS Select the type of the
overwriting level; LOW,
MEDIUM, or HIGH for
deleting HDD data.
(This setting is enabled
only when the GP-1070
is installed.)
0: LOW
1: MEDIUM
2: HIGH
1
1424
Data
overwrite
option
HDD data clearing type
setting (forcible clearing)
ALL
0
<0-2>
SYS Select the type of the
overwriting level; LOW,
MEDIUM, or HIGH for
deleting HDD data.
(This setting is enabled
only when the GP-1070
is installed.)
0: LOW
1: MEDIUM
2: HIGH
1
1426
Data
overwrite
option
Forcible HDD data
clearing
ALL
-
-
HDD data is cleared in
the procedure set in 08-
1424.
*
This setting is
enabled only when
the GP-1070 is
installed.
3
Setting mode (08)
Code
Classific
ation
Items
Functi
on
Default
<Acceptable
value>
Boa
rd
Contents
Proce
dure
Содержание e-studio205L
Страница 6: ......
Страница 10: ......
Страница 336: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 96 ...
Страница 354: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 4 18 ...
Страница 404: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 5 50 ...
Страница 576: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 14 Engine ROM Fig 8 8 ...
Страница 626: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 9 10 ...
Страница 664: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 11 2 ...
Страница 670: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved REVISION RECORD 2 ...
Страница 671: ......
Страница 672: ......