2
© 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO205L/255/305/355/455
SELF-DIAGNOSIS MODES
2 - 1
2. SELF-DIAGNOSIS MODES
2.1
Overview
Starting each mode
Shut down the equipment by pressing the [ON/OFF] button for a few seconds, then turn OFF the main
switch. Turn ON the main switch while pressing two digital keys designated to each mode (e.g. [0] and
[5]) simultaneously.
Note:
If the normal mode is started instead of self-diagnosis mode, start the equipment in the self-
diagnosis mode again.
Exiting from self-diagnosis modes
Shut down the equipment by pressing the [ON/OFF] button for a few seconds to exit from the self-
diagnosis mode.
List of modes
Note:
When the optional FAX unit is installed, Faxes received automatically during the self-diagnosis
mode may not be printed out. Be sure to disconnect the modular code from the line connectors
(LINE1, LINE2) of the equipment before starting the self-diagnosis mode. Also, be sure to finish
the self-diagnosis mode by turning the power OFF and back ON before connecting the modular
code.
Mode
For start
Contents
For exit
Display
Control panel
check mode
[0]+[1]+
POWER ON
All LEDs on the control panel are lit, and all
the LCD pixels blink.
POWER
OFF/ON
Test mode
[0]+[3]+
POWER ON
Checks the status of input/output signals.
POWER
OFF/ON
100% C A4
TEST MODE
Test print
mode
[0]+[4]+
POWER ON
Outputs the test patterns.
POWER
OFF/ON
100% P A4
TEST PRINT
Adjustment
mode
[0]+[5]+
POWER ON
Adjusts various items.
POWER
OFF/ON
100% A A4
TEST MODE
Setting mode
[0]+[8]+
POWER ON
Sets various items.
POWER
OFF/ON
100% D
TEST MOD
List print
mode
[9]+[START]
+POWER ON
Prints out the data lists of the codes 05 and
08, PM support mode, pixel counter, error
history, firmware upgrade log and power ON/
OFF log, and also outputs them in a CSV
format.
POWER
OFF/ON
100% L A4
LIST PRINT
PM support
mode
[6]+[START]
+POWER ON
Clears each counter.
POWER
OFF/ON
100% K
TEST MODE
EPU
replacement
mode
[7]+[START]
+POWER ON
When replacing EPU, this mode is available
for the installation of the EPU whose initial
detection is possible.
POWER
OFF/ON
Firmware
update mode
[8]+[9]+POWER ON
or
[4]+[9]+POWER ON
Performs updating of the system firmware.
POWER
OFF/ON
Содержание e-studio205L
Страница 6: ......
Страница 10: ......
Страница 336: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 96 ...
Страница 354: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 4 18 ...
Страница 404: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 5 50 ...
Страница 576: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 14 Engine ROM Fig 8 8 ...
Страница 626: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 9 10 ...
Страница 664: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 11 2 ...
Страница 670: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved REVISION RECORD 2 ...
Страница 671: ......
Страница 672: ......