(10) Measure the distance (L) between the stitching position and the folding position. Then perform
“positive width adjustment” or “negative width adjustment” to suit the relationship between the
stitching position and the folding position.
• If the stitching position is below the folding position, perform “positive width adjustment.”
• If the stitching position is above the folding position, perform “negative width adjustment.”
Fig. 3-95
(11) Change the settings of bits 6 through 8 on SW504 referring to the following table.
• If the width adjustment is 0
The stitching position and the folding position match, requiring no change.
• If for “positive width adjustment”
Set SW504 so that the difference resulting from subtraction of the interval from the
appropriate setting in the table below is provided.
Example: If SW504 is currently set to +2 and the interval is +1 mm, set SW504 to reflect - 2.
• If for “negative width adjustment”
Set SW504 so that the sum resulting from addition of the interval from the appropriate setting
in the table below is provided.
Example: If SW504 is currently set to -1 and the interval is -0.5mm, set SW504 to r1.
(12) Set SW504 bits 1 to 4 to OFF.
DIPSW1 bit settings
Setting
(in units of 0.5 mm)
Bit 6
Bit 7
Bit 8
OFF
ON
ON
+3
OFF
ON
OFF
+2
OFF
OFF
ON
+1
OFF
OFF
OFF
0
ON
OFF
ON
-1
ON
ON
OFF
-2
ON
ON
ON
-3
Do not use the following setting
Bit 6
Bit 7
Bit 8
ON
OFF
OFF
Mark
Stitching position
Folding position
Unit: mm
Example: If L is 0.5 mm, provide "-0.5 mm".
Mark
Folding position
Stitching position
Unit: mm
Example: If L is 1 mm, provide "+1 mm".
Positive Width Adjustment
Negative Width Adjustment
L
L
Содержание e-studio205L
Страница 6: ......
Страница 10: ......
Страница 336: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 96 ...
Страница 354: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 4 18 ...
Страница 404: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 5 50 ...
Страница 576: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 14 Engine ROM Fig 8 8 ...
Страница 626: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 9 10 ...
Страница 664: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 11 2 ...
Страница 670: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved REVISION RECORD 2 ...
Страница 671: ......
Страница 672: ......