3
© 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO205L/255/305/355/455
ADJUSTMENT
3 - 37
3.6.10
Background processing offset adjustment
The density of background is adjusted.
<Adjustment Mode (05)>
<Procedure>
The procedure is the same as that of
P.3-32 "3.6.2 Density adjustment".
Black
Item to be adjusted
Remarks
Original mode
Text/
Photo
Photo
User
Custom
Gray
Scale
8400
8402
8404
8403
Background density
adjustment
/ Automatic density
adjustment
The larger the value is, the lower
the density of the image
background (low density section)
becomes.The smaller the value
is, the higher the density of the
image background (low density
section) becomes.Acceptable
values: 0 to 255
(Default: 128)
8405
8407
8409
8408
Background density
adjustment
/ Manual density
adjustment
Color
Item to be adjusted
Remarks
Original mode
Text
Photo
Printed
Image
User
Custom
8385
8386
8387
8389
Background density
adjustment
/ Automatic density
adjustment
The larger the value is, the lower
the density of the image
background (low density section)
becomes.The smaller the value
is, the higher the density of the
image background (low density
section) becomes.
Acceptable values: 0 to 255
(Default: 128)
8390
8391
8392
8394
Background density
adjustment
/ Manual density
adjustment
RADF
Item to be
adjusted
Remarks
Black/
Gray
Scale
Color
7468
8395
Background
density processing
/ RADF scanning
Adjusts the density of background for RADF scanning. The
larger the value is, the lower the density of the background
and the low density section (e.g. light text or lines)
becomes. The smaller the value is, the higher the density
of them becomes.
Acceptable values: 0 to 255
(Default: 128)
Содержание e-studio205L
Страница 6: ......
Страница 10: ......
Страница 336: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 96 ...
Страница 354: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 4 18 ...
Страница 404: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved PREVENTIVE MAINTENANCE PM 5 50 ...
Страница 576: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 8 14 Engine ROM Fig 8 8 ...
Страница 626: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved POWER SUPPLY UNIT 9 10 ...
Страница 664: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved WIRE HARNESS CONNECTION DIAGRAMS 11 2 ...
Страница 670: ...e STUDIO205L 255 305 355 455 2009 TOSHIBA TEC CORPORATION All rights reserved REVISION RECORD 2 ...
Страница 671: ......
Страница 672: ......