e-STUDIO2040C/2540C/3040C/3540C/4540C
© 2011 TOSHIBA TEC CORPORATION All rights reserved
6 - 5
6. Printer-specific Adjustments (GA-1211)
Methods of calibration for GA-1211
Method
Measurement device (interface)
Feature
DTP-32
X-Rite DTP32 automatic densitometer
(RS-232C)
DTP32 Series II
X-Rite DTP32 Series II automatic densitometer
(RS-232C)
DTP41 Calibration
X-Rite DTP41 automatic spectrophotometer
(RS-232C)
ES-1000 *
Spectrophotometer ES-1000 hand-held
spectrophotometer (USB)
The accuracy of
calibration is
upgraded due to the
use of a measurement
device.
ColorCal
The copier’s built-in scanner and the Kodak
grayscale appended to GA-1211.
The more
detailed
setting is
available with
the PC
Calibrating from the
copier touch panel
The copier’s built-in scanner and the Kodak
grayscale appended to GA-1211.
Calibration is
performed easily
because the scanner
function of the MFP
is used but any
measurement device
is not used.
The setting is
easily
performed
from the MFP
touch panel.
* ES-1000 above is an optional device of EFI, which is originally manufactured by Gretag Macbeth (I1) but
customized exclusively for EFI. The ES-1000 is hardware key for optional EFI Color Profiler or Spot-On,
and these options will not be started unless the ES-1000 is connected to them.
Simple calibration (ColorCal)
ColorCal enables calibration for the GA-1211 by measuring the toner density using the built-in scanner of the
MFP, without preparing any expensive measurement devices such as spectrometers or densitometers.
ColorCal can be operated by starting Calibrator on a computer connected to the MFP, or from the control
panel of the MFP without a computer. Note that the accuracy of the calibration with ColorCal is lower than
that of calibration with a measurement device because the built-in scanner of the MFP is not originally
developed as a measurement device. If problems such as false contour, color spots in gray areas or color
imbalance occurred after calibration with ColorCal, such problems are often resolved by recalibrating with a
measurement device such as DTP-32 or ES-1000.
The differences between the ColorCal calibrations from the touch panel of the MFP and from Calibrator are
shown below.
Содержание e-studio 2040c
Страница 1: ...File No SME11002600 R110621J9200 TTEC Ver00_2011 08 ...
Страница 3: ......
Страница 4: ...Revision Record File No SME11002600 Date Rev No Item Descriptions Remarks ...
Страница 5: ......
Страница 8: ......
Страница 13: ......
Страница 127: ......
Страница 253: ......
Страница 293: ......