6-8
Alignment and Adjustments
(2) Linearity adjustment (Guide roller S, T adjustment)
1) Playback the Mono Scope alignment tape (SP mode).
2) Observe the video envelope signal on an oscilloscope (triggered by the video switching pulse).
3) Make sure the video envelope waveform (at its minimum) meets the specification shown in Fig. 6-11.
If it does not, adjust as follows :
Note :
a=Maximum output of the video RF envelope.
b=Minimum output of the video RF envelope at the entrance side.
c=Minimum output of the video RF envelope at the center point.
d=Maximum output of the video RF envelope at the exit side.
4) If the section A in Fig. 6-12 does not meet the specification, adjust the guide roller S up or down.
5) If the section B in Fig. 6-12 does not meet the specification, adjust the guide roller T up or down.
Fig. 6-11 Envelope Waveform Adjustment
a
a b c d
c,b,d/a 63%
b
c
d
Fig. 6-12 Adjustment Points
A
B
A
B
H'D SWITCHING PULSE
ENVELOPE
Содержание D-VR3SU
Страница 3: ...CONTENTS ...
Страница 4: ...MEMO ...
Страница 10: ...Precautions 1 6 MEMO ...
Страница 22: ...Reference Information 2 12 MEMO ...
Страница 24: ...Product Specification 3 2 MEMO ...
Страница 25: ...4 1 4 Operating Instructions ...
Страница 88: ...5 22 Disassembly and Reassembly MEMO ...
Страница 100: ...6 12 Alignment and Adjustments MEMO ...
Страница 115: ...Circuit Operating Descriptions 7 15 Fig 7 12 IC601 Block Diagram ...
Страница 148: ...Circuit Operating Descriptions 7 48 MEMO ...
Страница 160: ...VCR Deck Operating Description 8 12 Fig 8 14 Mecha Timing Chart ...
Страница 174: ...VCR Deck Operating Description 8 26 MEMO ...
Страница 200: ...Exploded View and Parts List 10 8 MEMO ...
Страница 216: ...11 16 Electrical Parts List MEMO ...
Страница 217: ...1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...