g033582
Figure 103
1.
Filter head
4.
Gasket (drain plug)
2.
Gasket (bowl)
5.
Drain cap
3.
Filter element
6.
Bowl
3.
Rotate the drain cap counterclockwise and
remove it from the bowl of the pressure filter
(
).
Note:
Allow the bowl to drain completely.
4.
Rotate the bowl counterclockwise and remove
the filter head (
).
5.
Remove the old pressure filter element (
Note:
Discard the old filter.
6.
Check the gasket for the drain plug (located
inside the bowl) and the gasket for bowl (located
inside the filter head) for damage and wear
(
).
Note:
Replace any damaged or worn gaskets
for the plug, bowl, or both.
7.
Install the new pressure filter element into the
filter head (
Note:
Ensure that the filter element is firmly
seated into the filter head.
8.
Install the bowl onto the filter head, and tighten
by hand (
).
9.
Assemble the drain cap onto the fitting at the
bottom of the bowl, and tighten the cap by hand
(
).
Changing the Nozzle Filter
Note:
Determine the appropriate nozzle filter mesh
size that you need for your job; refer to
Nozzle-Tip Filter (Optional) (page 66)
.
1.
Park the machine on a level surface, engage the
parking brake, shut off the sprayer pump, shut
off the engine, and remove the key.
2.
Remove the nozzle from the spray turret (
g209504
Figure 104
1.
Spray turret
3.
Nozzle
2.
Nozzle filter
3.
Remove the old nozzle filter (
Note:
Discard the old filter.
4.
Install the new nozzle filter (
Note:
Ensure that the filter is fully seated.
5.
Install the nozzle onto the spray turret (
Inspecting the Sprayer
Pump
Service Interval:
Every 400 hours/Yearly (whichever
comes first)—Inspect the pump
diaphragm and replace if necessary.
(see an Authorized Toro Service
Distributor).
Every 400 hours/Yearly (whichever comes
first)—Inspect the pump check valves and
replace if necessary. (see an Authorized Toro
Service Distributor).
73
Содержание Multi Pro WM
Страница 91: ...Schematics g209531 Flow Diagram Sprayer System Rev B 91...
Страница 92: ...Notes...
Страница 93: ...Notes...
Страница 94: ...Notes...