Troubleshooting the Spray System
Problem
Possible Cause
Corrective Action
1. The electrical connection on the
section valve is dirty or disconnected.
1. Turn the valve off manually. Disconnect
the electrical connector on the valve
and clean all leads, then connect it.
2. There is a blown fuse.
2. Check the fuses and replace them as
necessary.
3. There is a pinched hose.
3. Repair or replace the hose.
4. A section bypass is improperly
adjusted.
4. Adjust the section bypass.
5. There are damaged section valve.
5. Contact your Authorized Service
Dealer.
A section does not spray.
6. The electrical system is damaged.
6. Contact your Authorized Service
Dealer.
A section does not turn off.
1. The section valve is damaged.
1. Disassemble the section valve; refer
to the section Cleaning the Sprayer
Valves. Inspect all of the parts and
replace any that are damaged.
A section valve is leaking.
1. A seal is worn or damaged.
1. Disassemble the valve and replace
the seals using the Valve Repair
Kit; contact your Authorized Service
Dealer.
1. The section bypass is improperly
adjusted.
1. Adjust the section bypass.
2. There is an obstruction in the section
valve body.
2. Remove the inlet and outlet
connections to the section valve
and remove any obstructions.
A pressure drop occurs when you turn on
a section.
3. A nozzle filter is damaged or clogged.
3. Remove and inspect all nozzles.