2.
Assemble the master-section-valve manifold,
gasket, and master-section-bypass valve with a
clamp tightened by hand (
A).
3.
Align the flange of the master-section-valve
manifold, a gasket, and the agitation-valve
manifold (
B).
4.
Assemble the master-section-valve manifold,
gasket, and agitation-valve manifold with a
clamp tightened by hand (
B)
5.
Align the flange of the master-section-valve
manifold, a gasket, and the master-section
house (
6.
Assemble the master-section-valve manifold
and socket with a clamp tightened by hand
(
B).
7.
Secure the end-cap fitting to the outlet fitting by
inserting a retainer into the outlet fitting (
8.
Assemble the agitation valve to the valve mount
with the flanged-head bolt and flanged locknut
that you removed in step
of
Master-Section-Manifold Valve (page 60)
and
torque the nut and bolt to 1017 to 1243 N∙cm
(90 to 110 in-lb).
Installing the Section Manifold
Valve
1.
Insert the upper end-cap fitting of the manifold
valve into the bypass fitting (
A).
Note:
If needed, loosen the mounting hardware
for the bypass fitting to provide clearance.
g028245
Figure 78
1.
Flange (reducer coupling)
6.
Socket (outlet fitting)
2.
Socket (bypass fitting)
7.
Retainer
3.
Bypass fitting
8.
Flange (manifold—section
valve)
4.
Flange (adjacent
manifold—agitation valve)
9.
Gasket
5.
End-cap fitting (manifold
valve assembly)
10.
Flange clamp
2.
Secure the end-cap fitting to the bypass fitting
by inserting a retainer into the socket of the
bypass fitting (
A).
3.
Assemble the outlet fitting onto the lower
end-cap fitting of the manifold valve (
4.
Secure the end-cap fitting to the outlet fitting by
inserting a retainer into the socket of the outlet
fitting (
A).
5.
Align a gasket between the flanges of the
reducer coupling and the section valve manifold
(
B).
6.
Assemble the reducer coupling, gasket, and
section valve manifold with a clamp and tighten
by hand (
B).
7.
If installing the 2 left most section valves, align
a gasket between the flanges of the 2 adjacent
section valve manifolds (
8.
Assemble the 2 adjacent section valve manifolds
and gasket with a clamp and tighten by hand
(
B).
9.
For the left or right boom section valves,
assemble the valves to the valve mount with
the flanged-head bolt and flanged locknut
that you removed in step
of
Section-Manifold Valve (page 61)
and torque the
nuts and bolts to 10 to 12 N∙m (90 to 110 in-lb).
66
Содержание Multi Pro 1750
Страница 17: ...g033286 Figure 6 1 Right section 4 Fresh water tank 2 Boom transport cradle 5 Operator s seat 3 Left section 17...
Страница 72: ...Schematics g028078 Sprayer System Schematic Rev DWG 125 0698 Rev B 72...
Страница 73: ...Notes...
Страница 74: ...Notes...