Starting and Operating Problems (machine
serial number above 31500000)
Problem
Possible Cause
Corrective Action
The fuel tank is empty.
Fill the fuel tank; refer to the machine
Operator’s Manual
.
The engine oil is below the minimum
level.
Fill the engine crankcase with oil; refer
to the machine
Operator’s Manual
.
The engine On/Off switch is in the O
FF
position.
Set the engine On/Off switch to the
R
UN
position.
The parking brake is disengaged and
the operator seat is unoccupied.
Engage the parking brake or have
someone occupy the operator seat.
The motion control linkage is not
properly adjusted.
Verify motion control operation and
adjust as necessary; refer to Adjusting
the Control Pedal Return to Neutral
Mechanism in Chapter 5 – Hydraulic
System.
The engine On/Off switch, low oil level
switch, parking brake switch, operator
seat switch, or neutral switch are not
functioning.
Test the switch; refer to Testing the
Electrical Components in Chapter 6 –
Electrical System.
The ground connection at the engine is
loose or corroded.
Test, clean, or repair the ground
connection at the engine.
The interlock module is not functioning.
Test the interlock module; refer to
Testing the Electrical Components in
Chapter 6 – Electrical System.
Nothing happens when you attempt to
start the engine.
The engine ignition module is not
functioning.
Test the ignition module; refer to the
Honda Engine Service Manual
. Contact
your local Honda Engine Dealer or
visit http://engines.honda.com for any
assistance.
The parking brake switch or operator
seat switch has been bypassed.
Remove any circuit bypass and connect
the switch to the machine wire harness.
The brake switch is not functioning.
Test the switch; refer to Testing the
Electrical Components in Chapter 6 –
Electrical System.
The seat switch is not functioning.
Test the switch; refer to Testing the
Electrical Components in Chapter 6 –
Electrical System.
The engine starts with the operator’s
seat unoccupied and the parking brake
disengaged.
The interlock module is not functioning.
Test the interlock module; refer to
Testing the Electrical Components in
Chapter 6 – Electrical System.
The motion control linkage is not
properly adjusted.
Verify motion control operation and
adjust as necessary; refer to Adjusting
the Control Pedal Return to Neutral
Mechanism in Chapter 5 – Hydraulic
System.
The neutral switch is not functioning.
Test the switch; refer to Testing the
Electrical Components in Chapter 6 –
Electrical System.
The engine starts with the either motion
control pedal depressed.
The interlock module is not functioning.
Test the interlock module; refer to
Testing the Electrical Components in
Chapter 6 – Electrical System.
The parking brake is engaged.
Disengage the parking brake.
There is no operator in the operator
seat.
Occupy the operator seat.
The engine starts but stops when either
traction pedal is pushed to a M
OVE
position.
The parking brake switch or operator
seat switch is not functioning.
Test the switch; refer to Testing the
Electrical Components in Chapter 6 –
Electrical System.
GreensPro
™
1240/1260
Page 3–3
Troubleshooting: Starting and Operating Problems
(machine serial number above 31500000)
14211SL Rev A
Содержание GreensPro 1240
Страница 4: ...Reader Comments Page 4 GreensPro 1240 1260 14211SL Rev A...
Страница 8: ...Preface Page 8 GreensPro 1240 1260 14211SL Rev A...
Страница 14: ...Safety Safety and Instructional Decals Page 1 6 GreensPro 1240 1260 14211SL Rev A...
Страница 30: ...Specifications and Maintenance Special Tools Page 2 16 GreensPro 1240 1260 14211SL Rev A...
Страница 38: ...Troubleshooting Traction Circuit Problems GreensPro 1260 Page 3 8 GreensPro 1240 1260 14211SL Rev A...