WARNING
Battery terminals or metal tools could short
against metal tractor components causing
sparks. Sparks can cause the battery gasses
to explode, resulting in personal injury.
•
When removing or installing the battery,
do not allow the battery terminals to touch
any metal parts of the tractor.
•
Do not allow metal tools to short between
the battery terminals and metal parts of the
tractor.
WARNING
Incorrect battery cable routing could damage
the tractor and cables causing sparks. Sparks
can cause the battery gasses to explode,
resulting in personal injury.
If corrosion occurs at the terminals,
disconnect the cables, negative (-) cable
first, and scrape the clamps and terminals
separately. Reconnect the cables, positive
(+) cable first, and coat the terminals with
petroleum jelly.
•
Always disconnect the negative (black)
battery cable before disconnecting the
positive (red) cable.
•
Always connect the positive (red) battery
cable before connecting the negative
(black) cable.
Storing the Battery
If the machine will be stored more than 30 days,
remove the battery and charge it fully. Either store
it on the shelf on the machine. Leave the cables
disconnected if it is stored on the machine. Store
the battery in a cool atmosphere to avoid quick
deterioration of the charge in the battery. To prevent
the battery from freezing, make sure it is fully charged.
The specific gravity of a fully charged battery is
1.265–1.299.
Locating the Fuses
The fuses in the machine’s electrical system are
located under the seat (
).
g014617
Figure 46
1.
Fuses
2.
50 A fuse for radiator fan
(behind parts illustrated)
Fuse Layout
Lift Reel
E-Reel Enable
Over Temp
7.5 A
Reel Engage
Lights
Lift/Lower
Leak Detector
Fan
15 A
7.5 A
Start/Run
Starter
Diag. Lights
Glow
15 A
7.5 A
Run
ECM Logic
Power
10 A
2 A