•
Better results are obtained if the sprayer is moving
when spray controls are turned on.
•
Watch for changes in the application rate that may
indicate that your speed has changed beyond the
range of the nozzles or there is a problem with the
spray system.
Note:
Make sure the machine has been calibrated
properly before starting spray application
1.
Make sure the spray pump is on.
2.
Drive to the work area to be sprayed.
3.
Adjust the spray pressure to the appropriate
setting.
4.
Turn on the appropriate spray control:
The sprayer and spreader can be operated
either together or individually (spray liquid and
spread granular at the same time or separately).
Regardless of the situation, make sure that the
machine is running at full throttle.
When finished spraying, turn off the spray
control lever and the spray pump switch.
The spray pump switch can be left on for tank
agitation.
To use the spray wand:
WARNING
Spray wand traps liquids under high
pressure, even when engine is off. High
pressure spray discharge could cause
serious injury or death.
•
Keep clear of nozzle and do not direct
spray or stream at people, pets, or
non-work area property.
•
Do not direct spray on or near
electrical power components or
source.
•
Do not repair spray wand, hoses,
seals, nozzle, or other wand
components; replace them.
•
Do not attach hoses or other
components to the end of the spray
wand nozzle.
•
Do not attempt to disconnect the
spray wand from the unit while the
system is pressurized.
•
Do not use spray wand if trigger lock
is damaged or missing.
•
Do not keep spray wand in
locked-open position when job
is complete.
A.
Remove the wand from the holder on the
right side of the machine.
B.
Turn the spray wand flow valve on.
C.
Firmly grip and hold the spray wand. Point
it in the direction to be sprayed.
Note:
Wand may kick back; make sure to
hold the wand securely.
D.
Adjust the spray wand flow using the wand
flow control.
E.
Squeeze the trigger to the spray wand
handle to begin spraying; lock the trigger in
place if desired.
5.
When finished spraying:
•
From the front spray nozzles:
Turn the three section valves off.
•
From the spray wand:
A.
Release the trigger and its lock (if
applicable).
B.
Turn the spray wand flow valve off
C.
Return the wand back to its holder.
Important:
Contact an Authorized Service Dealer
if the spreader-sprayer fails to operate properly.
Cleaning the Sprayer
Clean the spray system after
each
spraying session.
Important:
Always empty and clean the sprayer
immediately after each use. Failure to do so may
cause the chemicals to dry or thicken in the lines,
clogging the pump and other components.
To properly clean the spray system:
•
Use three separate rinses.
•
Use a minimum of 19 L (5 US gallons) for each
rinse.
•
Use the cleaners and neutralizers as
recommended by the chemical manufacturers.
•
Use pure clean water (no cleaners or neutralizers)
for the
last
rinse.
WARNING
Do not clean spray nozzles by mouth or
blowing through them. Swallowing or inhaling
chemicals could cause serious injury or
death.
Replace all worn and damaged nozzles.
Make sure nozzles are installed correctly.
36
Содержание 34242
Страница 8: ...decal146 0776 146 0776 8...
Страница 59: ...Schematics g402879 Electrical Schematic Rev B 59...