11
2. Lift the squeegee by rotating the
squeegee lift lever upwards (5).
3. Bring the machine to an
appropriate place for drain the
tank.
ATTENTION:
The machine is not equipped with
a parking brake, therefore do not
leave it on slopes.
DAILY MAINTENANCE
Emptying and cleaning of the
recovery tank
To empty and clean the recovery
tank.
1. Switch off the machine by
pressing the main switch.
2. Take off the suction cover (19)
after rotating the levers (18).
3. Take off the squeegee hose (17).
4. Lift and take off the recovery
tank (16) holding it with the its
handles located on the front and
back of the tank.
Empty the recovery tank into
appropriate containers, according
to the standard norms for the liquid
disposal.
5. Clean and rinse the tank and
allow to air dry.
6. Reassemble everything.
ATTENTION:
This operation must be carried out
using gloves to protect from
contact with dangerous solutions.
Emptying and cleaning the
solution tank
To empty solution remaining in the
solution tank:
1. Bring the machine to an
appropriate place for draining the
tank.
2. Switch off the machine pressing
the main switch.
3.Unscrew the cap (15) of the
solution tank.
4. Unscrew the drain plug (13)
placed in the rear low left part of
the machine.
ATTENTION:
This operation must be carried out
using gloves to protect from contact
with dangerous solutions
.
Vacuum filter cleaning
1. Take off the vacuum cover (19)
after rotating the blocking levers
(18).
2. Take off the filter with the float,
bending the filter edge to release it
from the screws on the cover.
3. Clean all parts with a water jet
and especially the surfaces and
filter bottom.
4. Carry out the recovery tank
cleaning operations.
5. Reassemble everything.
Positioning the machine for
maintenance and parking
The machine can assume a vertical
positioning, tipped over at the
back, after having folded the
handle bar onto the machine.
This position allows the unit to be
stored in a small space and
simplifies maintenance operations.
To rotate the machine to a storage
position it is necessary to:
1. Switch off the main switch.
2. Check that both tanks are empty,
otherwise empty them (see under
“EMPTYING AND CLEANING
THE RECOVERY TANK” and
“EMPTYING AND CLEANING
THE SOLUTION TANK”).
3. Pull up on the handle bar release
lever (8) near the handle bar.
4. Rotate the handle bar towards
the tank keeping the release lever
(8) pulled.
5. Release the lever (8) to obtain
the handle bar locking posotion.
Содержание 99414