22
TROUBLESHOOTING
6. Remove vacuum hose from squeegee by pulling
hose off squeegee throat.
7. With the vacuum motor on, place your hand over
the vacuum hose intake. If suction is strong, a
blockage is in the squeegee throat.
Clear this blockage by pushing a screwdriver, or
any similar tool, downward through the top of
the squeegee throat.
NOTE: Performing these maintenance
procedures will avoid problems with the
recovery system requiring outside repair
service. Always be very sure the vacuum
system is clear of any blockage before calling
for service.
Poor Solution Flow
If an inadequate supply of solution is reaching the floor, check the solution hoses for kinks.
These hoses are connected to the brush drive assembly. If there are no kinks in the solution
hoses, pull the hoses from the brush cover fitting and check the entire line for blockage.
https://harrissupplyind.com - To Order Parts Call 608-268-8080