TROUBLESHOOTING
Check each cell with a hydrometer before and after charging to determine it batteries are weak.
Do not charge or use batteries when the liquid in any one or more cells measures less than
1.150 specific gravity. A fully charged battery should read 1.270 or better after cooling 1/2 hour.
Batteries that have been properly charged and still do not reach a full charge should be
discarded. One defective battery can weaken the other batteries. Replace the defective battery
if the battery pack is less than two years old. If over two years, replace the entire battery pack.
Daily Battery Maintenance Precautions
1. Add distilled water only.
2. Never add acid.
3. Keep vent caps tight when operating.
4. Keep battery tops clean and dry.
5. Keep water level 1/4” above cell plates.
6. Keep metal and excessive heat away from batteries.
7. Use TORNADO charger with correct voltage and current rating.
TROUBLESHOOTING PERFORMANCE SYMPTOMS
Poor Solution Pickup
—
Vac motor not running;
Vac filter is clogged;
Recovery tank is full;
Squeegee or vac hose clogged, broken, disconnected;
Poor or no seal at filter, at squeegee or at vac motor;
Worn or misaligned squeegee blades;
Incorrect squeegee pressure;
Swing mechanism not functioning properly.
Squeegee Leaving Streaks
—
Floors not properly swept; debris on blades;
Blades torn or otherwise damaged;
Solution Feed/Shutoff Problems — Clogging of screen, hose or valve; control rod disconnected.
Inadequate Scrub, Strip or Buff
—
Brush motor not working - overload tripped;
Excessive brush or pad wear;
Going over very dirty spots too last;
Inadequate solution feed.
Losing Running Time
—
Batteries or charger need servicing;
High current draw for high brush pressure.