5- INSTALLATION
TF21/44R/T
5.3-
INSTALLATION OF THE POWER SUPPLY UNIT
BEFORE INSTALLING THE FEEDING UNIT PERFORM THE CORRECT INSTALLATION OF
THE SENSORS (SEE PAR.5.2) AND THE WIRING OF THE CONNECTION WIRES OF THE
SAME.
1)
Open the package
(par.3.6)
and extract the various components;
2)
Select the input position on the feeding unit of the sensor wires and mark the related
drilling points;
3)
Open the cover of the feeding unit container;
IN THE COVER OF THE VERSION TF24 IT IS INSTALLED THE ELECTRONIC CARD THAT IS
CONNECTED BY THREE WIRES TO THE POWER TRANSFORMER. PAY UTMOST CARE
NOT TO DAMAGE THE ELECTRIC CONNECTIONS OR THE CONNECTION TO THE
TERMINALS.
4)
Using a suitable drill, perform holes having a diameter of 3.5 mm on the two
impressions prearranged for the fastening screws located on the bottom of the
container;
It is suggested to select them diagonally to each other avoiding the ones close to the
transformer;
5)
With a suitable drill, perform in the container holes having a diameter of 10 mm in the
inlet points of the sensor wires marked at
step 2
);
6)
In the holes having a 10 mm diameter mount the fairleads included in the standard
supply;
7)
Place the container in the pre-selected position and through the holes having 3.5 mm
diameter mark with a pencil the drilling points on the installation support (wall or
other) of the feeding unit. Check the perfect horizontal and vertical alignment;
8)
With a suitable drill, perform holes having a diameter corresponding to the dowels
and to the screws included in the standard supply;
9)
Mount the container of the feeding unit and tighten the screws definitively;
10)
Prearrange the wires of the sensors and of the motors to be connected placing them
suitably in order to perform a correct ordered and functional electric connection;
11)
Perform the electric connections in compliance with the provisions of
par. 5.8
and
with reference to the wiring diagram corresponding to the purchased feeding unit
model;
12)
Perform the final test, verifying the correct tripping of the sensors according to the
prescriptions of the following paragraph.
INSTALLATION AND USE INSTRUCTIONS
VER.1.0