TOPEX MobiLink
IP
Preliminary Manual
Figure 3: Connecting the cables
For
Ethernet network connection:
Use standard UTP network cable (CUT 5) fitted with RJ45 connectors at both ends.
The cable can be either straight-through or crossover, since the MobiLinkIP is auto-crossover.
One short length of RJ-45 cable is supplied with the TOPEX MobiLinkIP interface.
Use either a 10Base-T or a 100Base-T connection.
Figure 4: Connecting the LAN cable (UTP- CAT5)
The network cable is to be inserted with one end into the RJ-45 socket of the MobiLinkIP device
labelled
ETH
. The opposite end of the UTP cable can be inserted directly into a PC or in switches or
hubs. The STATUS indicator LED of the MobiLink case will light up showing physical connection and
will blink to indicate data traffic on the respective Ethernet interface.
P
ower supply:
TOPEX S.A. +4 021.408.39.00