Calibrate Blade
P/N 7010-0344
3-5
Calibrate Blade
The Blade Slope Sensor, bolted to the back of the machine's circle
assembly, measures the slope of the cutting edge. Cutting edge wear
is the reason for Blade Sensor Calibration.
To perform the Blade Slope Sensor Calibration:
1. Place the cutting edge of the blade firmly on the ground and mark
the location. This is position #1.
Push the "NEXT" button.
2. Wait 5 seconds until you hear a single beep.
Figure 3-7.
VIEW F ROM F RONT OF G RADER
NEXT
EXIT
CALIBRATE BLADE
Place cutting edge firmly
on ground and mark location.