Transducer Replacement Procedure (Sonic Tracker II)
P/N 7010-0344
6-5
4. Place the wire connectors of the new Transducer firmly on their
tabs (the gray wire connector is placed on the elevated tab). Place
the Ty-Wrap in the slot next to the elevated (gray wire) tab,
tighten and trim. DO NOT pinch the wires.
Figure 6-4.
5. "Feed" the wires back up into the Sonic Tracker II and seat the
Transducer into place (the two wire tabs have to sit down into the
extra deep area of the recess). Place the new "O"-ring around the
Transducer and seat firmly between the Transducer and the Sonic
Tracker II Transducer recess.
Figure 6-5.
6. Place the black Retaining Ring over the Transducer assembly
with the beveled edges out and the flat surface against the Sonic
Tracker II base. Line up the holes for the mounting screws (the
mounting screw holes are set to an irregular pattern. This ensures
the retaining ring will only lineup with the mounting holes one
way).
PLACE NEW TY-WRAP
AROUND WIRES
AND TIGHTEN
TRIM EXCESS
TY-WRAP
CAREFULLY PLACE
WIRE CONNECTORS
ON TABS
TRANSDUCER
WIRE CONNECTOR
PINS