![Topcon GPT-3000W Series Скачать руководство пользователя страница 88](http://html1.mh-extra.com/html/topcon/gpt-3000w-series/gpt-3000w-series_instruction-manual_1128632088.webp)
7-11
7 DATA COLLECTION
5
Press the [F1](MEAS) key.
Continuous measuring starts.
[F1]
6
Collimate point A0 using the horizontal motion
clamp and horizontal tangent screw.
Collimate A0
7
Show the horizontal distance of point A0.
[
]
8
Show the relative elevation of point A0.
●
Each time pressing [
] key, horizontal distance ,
relative elevation and slope distance are shown in
sequence.
[
]
9
Show N coordinate of point A0 or A1.
●
Each time pressing [
] key, N,E and Z
coordinate are shown in sequence.
[
]
10
Press the [F3](YES) key.
The data is recorded and the next measuring point
is displayed.
[F3]
OFFSET-MEASUREMENT
HR: 120°30'40"
HD*[n] < m
>measuring ...
OFFSET-MEASUREMENT
HR: 120°30'40"
SD* 12.345 m
>OK? [YES][NO]
OFFSET-MEASUREMENT
HR: 123°30'40"
SD: 12.345 m
>OK? [YES][NO]
OFFSET-MEASUREMENT
HR: 123°30'40"
HD: 6.543 m
>OK? [YES][NO]
OFFSET-MEASUREMENT
HR: 123°30'40"
VD: 0.843 m
>OK? [YES][NO]
OFFSET-MEASUREMENT
HR: 123°30'40"
N : –12.345 m
>OK? [YES][NO]
PT#
→
PT-12
PCODE :TOPCON
R.HT : 1.200 m
INPUT SRCH MEAS ALL
Содержание GPT-3000W Series
Страница 1: ...GPT 3000W SERIES GPT 3002W GPT 3003W GPT 3005W GPT 3007W PULSE TOTAL STATION INSTRUCTION MANUAL...
Страница 2: ......
Страница 140: ...12 4 12 SETTING ATMOSPHERIC CORRECTION...
Страница 141: ...12 5 12 SETTING ATMOSPHERIC CORRECTION...
Страница 181: ...APPENDIX 5...
Страница 182: ...Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG Inc USA and licensed to Topcon Corporation...
Страница 183: ......