![Topcon GPT-3000W Series Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/topcon/gpt-3000w-series/gpt-3000w-series_instruction-manual_1128632058.webp)
6-5
6 SPECIAL MODE (Menu Mode)
6.1.2 Missing Line Measurement (MLM)
Measurement for horizontal distance (dHD), slope distance (dSD), elevation (dVD) and horizontal
bearing (HR) between two target prisms.
It is possible to enter the coordinate value directly or calculate from coordinate data file.
MLM mode has two modes.
1: MLM-1 (A-B, A-C) :Measurement is A-B, A-C, A-D,......
2: MLM-2 (A-B, B-C) :Measurement is A-B, B-C, C-D,......
●
It is necessary to set the direction angle of the instrument.
[Example] MLM-1 (A-B, A-C)
●
Procedure of MLM-2 (A-B, B-C) mode is completely same as MLM-1 mode
Operating procedure
Operation
Display
1
After pressing the [MENU] key, press the [F4](P
↓
)
key to get the menu on page 2.
[MENU]
[F4]
2
Press the [F1] key.
[F1]
3
Press the [F2](MLM) key.
[F2]
4
Press the [F1] or [F2] key to select using
coordinate file.
[Example:F2 : DON’T USE]
[F2]
Prism A
Prism B
Prism C
Prism B
Prism A
Instrument
Instrument
MENU 2/3
F1:PROGRAMS
F2:GRID FACTOR
F3:ILLUMINATION P
↓
PROGRAMS 1/2
F1:REM
F2:MLM
F3:Z COORD. P
↓
MLM
F1:USE FILE
F2:DON’T USE
GRID FACTOR
F1:USE G.F.
F2:DON’T USE
Содержание GPT-3000W Series
Страница 1: ...GPT 3000W SERIES GPT 3002W GPT 3003W GPT 3005W GPT 3007W PULSE TOTAL STATION INSTRUCTION MANUAL...
Страница 2: ......
Страница 140: ...12 4 12 SETTING ATMOSPHERIC CORRECTION...
Страница 141: ...12 5 12 SETTING ATMOSPHERIC CORRECTION...
Страница 181: ...APPENDIX 5...
Страница 182: ...Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG Inc USA and licensed to Topcon Corporation...
Страница 183: ......