![Topcon GPT-3000W Series Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/topcon/gpt-3000w-series/gpt-3000w-series_instruction-manual_1128632151.webp)
17-2
17 CHECK AND ADJUSTMENT
17.2 Checking the Optical Axis
17.2.1Checking the optical axis of EDM and theodolite
To check if the optical axis of EDM and theodolite are matched, follow the procedure below.
It is especially important to check after adjustment of the eyepiece reticle is carried out.
1) Position a prism about 30 to 50m apart from GPT-3000W series .
2)Turn the power ON while pressing the [F1] key.
Adjustment mode menu 1/2 will appear.
3)Press the [F4](P
↓
) key to get the menu 2/2.
Press the [F1] key to select the EDM CHECK
mode.
4)Collimate the center of a prism by prism mode.
The buzzer will sound.
5)Press the [F4](hold) key to hold the quantity of
the light.
The mark "#" will appear on the right side of the
signal level indicator.
●
H direction confirmation (Do not move V direction).
6) Turn the horizon tangent screw, move the collimating point to the left side of prism gradually until
buzzer sound stops.
Check each of the optical axis of EDM and theodolite about prism mode and non-prism mode in order.
ADJUSTMENT MODE 1/2
F1:V ANGLE 0 POINT
F2:INST. CONSTANT
F3:V0 AXIS P
↓
ADJUSTMENT MODE 2/2
F1:EDM CHECK
P
↓
V: 90
°
10'10"
HR: 20
°
00'20"
SIGNAL:[
❙
❙
❙
❙
❙
]
EXIT NP/P HOLD
V: 90
°
10'10"
HR: 00
°
04'20"
SIGNAL:[
❙
❙
❙
❙
❙
] #
EXIT NP/P HOLD
Reticle
Prism
Содержание GPT-3000W Series
Страница 1: ...GPT 3000W SERIES GPT 3002W GPT 3003W GPT 3005W GPT 3007W PULSE TOTAL STATION INSTRUCTION MANUAL...
Страница 2: ......
Страница 140: ...12 4 12 SETTING ATMOSPHERIC CORRECTION...
Страница 141: ...12 5 12 SETTING ATMOSPHERIC CORRECTION...
Страница 181: ...APPENDIX 5...
Страница 182: ...Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG Inc USA and licensed to Topcon Corporation...
Страница 183: ......