19. CHANGING THE SETTINGS
116
&
Key backlight
The key backlight can be set to "ON" or "OFF". When "ON" the keys will be illuminated when
"Backlight (Bright)" is active.
&
EDM ALC
Set the light receiving status of the EDM. While carrying out continuous measurement, set this
item according to the measurement conditions.
• When EDM ALC is set to "Free," the instrument’s ALC will be automatically adjusted if an error
occurs as a result of the amount of light received. Set to "Free" when the target is moved during
measurement or different targets are used.
• When "Hold" is set, the amount of light received will not be adjusted until continuous
measurement is completed.
• If an obstacle intermittently obstructs the light beam during continuous measurement and the
"Signal off" error occurs, each time the obstruction occurs it takes some time for the amount of
light received to be adjusted and the measurement value displayed. Set to "Hold" when the light
beam used for measurement is stable but is frequently obstructed by obstacles such as people,
cars, or tree branches etc. preventing measurement from being performed.
$
• When the distance measurement mode is set to "Tracking" (target is moved during distance
measurement) the EDM ALC will be adjusted regardless of the EDM ALC setting.
&
Laser-pointer off
To save power, the laser-pointer is automatically turned off after the set time has elapsed.
&
Color setting
Set "Color" to "2" (monochrome) when strong sunlight reduces visibility of the display. When
"Auto" is selected, the instrument detects the ambient brightness level and automatically sets
the appropriate color setting accordingly.
C
G
• Do not block the instrument light sensor when "Color" is set to "Auto". The instrument will be
unable to gauge ambient brightness and the display will flicker as a result.
I
"EDM" tab
19.3
EDM Settings