95
15. SETTING-OUT MEASUREMENT
5. Sight the target and press
[MEAS]
. Measurement
begins and the measurement results are
displayed.
6. Press
[REM]
to start REM measurement.
The distance (height difference) and direction to
move the target until the sighting point and setting
out point are located is displayed on the
instrument.
Press
[STOP]
to stop measuring.
Find the setting-out point by moving the telescope
until the distance to the setting-out point reads 0m.
• Movement indicator (Red indicates that target
position is correct)
Q
: Move the telescope near the zenith
H
: Move the telescope near the nadir
HQ
: Telescope direction is correct
C
For details of other movement indicators:
"15.2 Distance Setting-out Measurement"
step 6
• Press
[CNFG]
to set setting out accuracy. When
the position of the target is within this range both
arrows will be displayed to indicate that the
target position is correct.
7. Press
{ESC}
to return to <SO data setting>.
Arrows indicate direction to move