19
a ) For P1—P36, Speed and inclination is divided into 16 segments. Each segment has the same time. The
speed after selecting will be avail in current segment. When run to next segment. It will sound 3 times in
advance. When finish 16 segments, the motor will stop with a long prompt sound.
b ) Press “
START
” key when running, it will pause. Press “
START
” key again, it will running, the record data will
keep on.
5.5. Press “
STOP
” key when running, the treadmill will slowly till stop. All will return to the default state.
5.6. In any state, pull off the safety key and the screen shows
“ E - 0 7 ”
with promote sound. The treadmill stops
running.
5.7. The controller always under the inspection. Treadmill will stop once the abnormal case happens. Window will
show the ERR message and sound.
5.8. Method of body fat testing
:
Press
“PROG”
key to select program
FAT
.
“DISTANCE”
window shows setting
program number and press
“MODE”
key to select program sequence number. Right
“TIME”
window shows
setting program parameter, and press
“
+
”
and
“
-
”
keys to set parameter.
a) Item number
F1:
means Sex, the 1(male), 2(female). Parameter setting range
:
1-2. Default value
:
1
;
b ) Item number
F3:
means Age, the range is 1-99, and the original is 25.
c ) Item number
F3:
means Height, the range is 100-220CM(39-87inch), the original is 170CM(67inch)
d) Item number
F 4 :
means Weight, the range is 20-150KG(44-330pound), the original is 70KG (154pound)
e) Item number
F 5 :
mean BMI, show you have finished the set item , and enter into body fat function. Put
two hands on the handle bar, wait for 8 seconds, and the window will show the BMI. Take the Asian people
for example,
BMI under 18 is under weight;
Between 18 and 24 is normal weight;
Between 25 and 28 is over weight;
And over 29 is obesity.
(
Ⅵ
). Fan
:
(
Optional
)
6.1.
When the fan stops, press the fan key and the fan starts running; when the fan is running, press the fan key, and the fan stops.
(
Ⅶ
). MP3
:
(
Optional
)
7.1. The console has a built-in dual channel sound, a switching mode power supply, and a non signal silent
function. The audio adapter is connected to the MP3 heatset jack and the audio input hole of the electronic
meter with a distributed audio adapter wire. This is s voice playback.
(
Ⅷ
). H R C
:
8.1. The default of HRC is three groups;the speed limitation of HRC1, HRC2, HRC3 is 9 km/h, 11 km/h and
13km/h.
8.2. HRC can set the range of methods, orders and parameter. When you press the program button to display the
HRC, press mode to confirm and go to the next setting group. It can start when you press the speed button to
set the final parameters set.
A: Age range
:
15-80 years old, the default is 25 years old.
B: Target heart rate(THR): (220-age)*0.6
C: The correction range of the target heart rate: 80-180
D: The default of time is 30 minutes. The correction range: 5-99 minutes.
8.3. Speed change
A: Changing frequency, HRC check the heart rate once every 30 seconds (heart rate has been shown).
B: When the user's heart rate is lower than the target heart rate 30 beats / min, the speed is increased 2.0