TOOLCRAFT 1601070 Скачать руководство пользователя страница 4

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in 

electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. 

This publication represent the technical status at the time of printing.  
© Copyright 2017 by Conrad Electronic SE. 

1601070_V1_1117_02_VTP_m_en

Operation

  Observe the safety instructions!

•  Hold the voltage tester so that a finger 

touches the top of the voltage tester. 

Do not use a glove. The human skin 

must be in direct contact with the con-

tact surface.

•  Then hold the blade tip of the volta-

ge tester to the electrical contact you 

would like to test. Make sure the sur-

face makes measurement possible. 

Oxidised or painted surfaces are unsu-

itable for measurement.

•  If the glow lamp lights up, there is a 

voltage (on two sides of the voltage 

tester are lens-like windows, through 

which you can see the lamp).

  In this way, you can quickly determine the opening of phase L, for example in a 

power socket.
Attention, important for operation:
•  When operating the voltage tester, it is important that the contact surface at the 

top touches human skin. Therefore, do not wear gloves or similar protection when 

using this device.

•  Please note under poor lighting conditions, (e.g., sunshine, bright ambient condi-

tions) or an unfavourable viewing angle or looking at an unfavourable angle, it may 

be difficult to detect whether the lamp is glowing. 

•  Display accuracy may be affected if you are standing on insulated surfaces (or 

wearing shoes) or measuring a non-grounded AC system.

•  The accuracy of the display can also be affected if the contact resistance of the 

skin is too high (e.g., dry skin or cornea). 

•  The amount of voltage is not displayed.
•  Under certain circumstances, the glow lamp may light up even if there is no volta-

ge (caused by e.g., static charge).

•  It is not possible to test the neutral conductor (N) or protective conductor (PE).
•  In principle, it is not possible to measure sockets with child protection possible 

because the design of the socket prevents inserting a single probe. 
Never bypass the child protection of the socket by, for example, plugging in ano-

ther object! Never use two single-pole voltage testers at the same time!

•  Owing to external influences, it may happen that the glow lamp does not light up 

(or the lamp does not shine bright enough) despite that there is a voltage.

•  The single-pole voltage tester is not suitable for reliably determining the absence 

of voltage according to DIN EN 61243-3 (VDE 0682-401).

•  Always test the voltage tester’s function and display first on an intact/functional/

sound voltage source before carrying out the actual test.

Care and cleaning

Use a clean, dry, soft cloth for cleaning. Do not use aggressive cleaning agents as these can 

cause discolouration. To prevent scratch marks, do not press too strongly on the surface when 

cleaning.
A defective glow lamp cannot be replaced. Dispose of the voltage tester in an environmentally 

correct manner.

Disposal

  

The product must not be disposed of with the household waste. Dispose of an un-

serviceable product in accordance with the relevant statutory regulations.

Technical data

Testable voltage ................................... 100 - 250 V/AC
Mains voltage, frequency range .......... 50 - 500 Hz
Standard .............................................. VDE 0680
Operating conditions ............................  Temperature -10 °C to +50 °C, max. 85% relative air 

humidity, noncondensing

Storage conditions ...............................  Temperature -10 °C to +60 °C, max. 85% relative air 

humidity, noncondensing

Measurements ..................................... Total length: 187 mm

.............................................................

Blade width: 4 mm

.............................................................

Blade thickness: 0.7 mm

.............................................................

Blade length: 99 mm

.............................................................

Handle diameter: 18 mm 

.............................................................

Handle length: 88 mm

Содержание 1601070

Страница 1: ...fgrund der Funktionsweise des einpoligen Spannungsprüfers kann es jedoch zu Problemen kommen Beachten Sie deshalb unbedingt das nächste Kapitel Bedie nung Bedienungsanleitung Einpoliger Spannungsprüfer Best Nr 1601070 Bestimmungsgemäße Verwendung Das Produkt dient zum Prüfen von Wechselspannungen im Bereich von 100 250 V AC mit einer Frequenz von 50 500 Hz Es darf nicht für andere Arbeiten verwend...

Страница 2: ...ßerdem durch einen zu hohen Übergangswider stand der Haut beeinträchtigt werden z B trockene Haut oder Hornhaut Die Höhe der Spannung wird nicht angezeigt In bestimmten Fällen kann die Glimmlampe aufleuchten obwohl keine Spannung anliegt verursacht durch z B statische Aufladung Eine Prüfung des Nullleiters N oder Schutzleiters PE ist nicht möglich Messungen an Steckdosen mit Kindersicherung sind p...

Страница 3: ...r the operation of the single pole voltage tester can cause problems It is therefore important to follow the instructions in the next chapter Operation Operating instructions Single pole voltage tester Item no 1601070 Intended use The product is designed to test AC voltages in the range of 100 250 V AC with a frequency of 50 500 Hz It is not intended for other applications For safety and approval ...

Страница 4: ... the contact resistance of the skin is too high e g dry skin or cornea The amount of voltage is not displayed Under certain circumstances the glow lamp may light up even if there is no volta ge caused by e g static charge It is not possible to test the neutral conductor N or protective conductor PE In principle it is not possible to measure sockets with child protection possible because the design...

Страница 5: ...ant passant à travers la résistance en série dans le détecteur de tension n est pas dangereux Cependant il suffit pour que la lampe néon s allume La fonctionnalité du détecteur de tension unipolaire peut cependant engendrer des problèmes C est pourquoi il faut respecter absolument le prochain chapitre Utili sation Mode d emploi Détecteur de tension unipolaire N de commande 1601070 Utilisation conf...

Страница 6: ...de contact de la peau trop élevée par ex peau sèche ou callosité Le degré de tension ne sera pas affiché Dans certains cas la lampe néon peut s allumer bien qu aucune tension ne soit présente causée par exemple par une tension statique trop élevée Il n est pas nécessaire de vérifier le conducteur neutre N ou le conducteur de protection PE Les mesures sur des prises de courant dotées d une sécurité...

Страница 7: ... ongevaarlijk Het is echter voldoende dat de glimlamp oplicht Op basis van de manier van werking van de enkelpolige spanningstester kan het echter problemen veroorzaken Het is daarom belangrijk om het volgende hoofdstuk Bediening in acht te nemen Gebruiksaanwijzing Enkelpolige spanningstester Bestelnr 1601070 Beoogd gebruik Het product dient om wisselstroomspanningen te testen in het bereik van 10...

Страница 8: ...ave kan bovendien beïnvloed worden door een te hoge contactweerstand van de huid bijv Droge huid of hoornvlies De hoeveelheid spanning wordt niet weergegeven In bepaalde gevallen kan de glimlamp oplichten ook al is er geen spanning inge schakeld veroorzaakt bijv door een statische lading Een test van de nulleider N of de beschermende geleider PE is niet mogelijk Metingen op contactdozen met kinder...

Отзывы: