TOOLCRAFT 1601070 Скачать руководство пользователя страница 3

b) Electrical safety

Attention, important note!
Only persons with relevant electro-technical knowledge and experience 

should carry out the installation! *)
If it is installed improperly, you risk:
•  your own life
•  the life of the person using the electrical system.
If it is not installed properly, you risk severe damage to property, e.g., by fire.
You face the risk of being held liable for personal injury and material damage. 
Contact an Electrician!
*) Specialist knowledge required for the installation:
In particular, the following expertise is required for installation:
•  the applicable „5 safety rules“: Switch off power; secure against switching back 

on; determine voltage-free status; earthing and short-circuiting; cover or fence off 

nearby live parts

•  Choose appropriate tools, meters and, if necessary, personal protective equip-

ment

•  Evaluation of the measurement results
•  Selection of the electrical installation material to ensure the shutdown conditions
•  IP protection types
•  Installation of the electrical installation material
•  Type of mains supply network (TN system, IT system, TT system) and the con-

nection conditions that follow from them (classical earthing, protective earthing, 

required additional measures, etc.)

If you do not have the expertise required for the installation, do not install it 

yourself, but entrust the work to a qualified electrician. 

c) Operation

•  Carefully inspect the voltage tester for damage before each use. If the voltage 

tester is damaged, do not use it. If so, dispose of it in an environmentally friendly 

manner. A defective glow lamp cannot be replaced.

•  The voltage tester must not get damp or wet. Never use the voltage tester in humid 

conditions (e.g., dew, fog, rain, etc.).

•  Only use the voltage tester at an ambient temperature of -10 °C to +50 °C.
•  Only use the voltage tester to test AC voltages in the range of 100 - 250 V/AC with 

a frequency of 50 - 500 Hz. The permissible voltage for the test procedure is also 

indicated on the voltage tester.
A test on DC voltages is not permitted (e.g., for photovoltaic systems).

•  Test the function of the voltage tester before each use on an intact/functional/

sound voltage source.

•  Do not use the voltage tester as a replacement for a conventional screwdriver. 

Heavy mechanical stress when loosening or tightening screws will damage the 

voltage tester.

•  Always use only one voltage tester. Never measure with two single-pole voltage 

testers at the same time.

Function

A series resistor and a light bulb are located between the blade point on one side of the voltage 

tester and the contact surface on the handle end.
Now If you connect the blade tip to a voltage-carrying line and touch the contact surface at 

the handle end with your fingertip (direct skin contact required!), a current will flow through 

the your body. 
Thanks to the series resistor in the voltage tester, the current is harmless. However, it is suffici-

ent for the glow lamp to light up.

  However, the operation of the single-pole voltage tester can cause problems. It is 

therefore important to follow the instructions in the next chapter „Operation“.

 Operating instructions

Single-pole voltage tester 

Item no. 1601070

Intended use

The product is designed to test AC voltages in the range of 100 - 250 V/AC with a frequency of 

50 - 500 Hz. It is not intended for other applications. 
For safety and approval reasons, do not convert and/or alter the product in any way. If you use 

the product for other purposes than those described above, the product may be damaged. 

Moreover, improper use involves risks such as short-circuits, fire, electric shocks, etc. Please 

read the operating instructions carefully and do not discard them. If you pass the product on to 

a third party, please include the operating instructions.
This product complies with the applicable national and European regulations. All names of 

companies and products are the trademarks of the respective owners. All rights reserved.

Package contents

•  Voltage tester
•  Operating instructions

Up-to-date operating instructions           

Download the latest operating instructions via the link www.conrad.com/downloads or scan the 

QR code. Follow the instructions on the website.

Explanation of symbols

  The lightning symbol inside a triangle is used when there is a potential risk of perso-

nal injury, such as electric shock.

  An exclamation mark inside a triangle indicates important instructions in this opera-

ting manual which must be adhered to.

  The arrow symbol indicates specific tips and advice on operation.

  Observe the operating instructions.

Safety instructions

Please read the operating instructions carefully and pay particular attention 

to the safety instructions. We do not assume liability for any injuries/mate-

rial damages resulting from failure to observe the safety instructions and the 

information in these operating instructions regarding the proper use of the 

product. Furthermore, in such cases, the warranty/guarantee will be null and 

void.

a) General information

•  The product is not a toy. Keep out of the reach of children and pets. 
•  Do not leave packing materials unattended. It may become a dangerous plaything 

for children.

•  Protect the product from extreme temperatures, direct sunlight, strong vibrations, 

high humidity, moisture, combustible gases, vapours and solvents.

•  Never expose the product to mechanical stress.
•  If safe operation is no longer possible, take the device out of service and secure 

it against unintended use. Safe operation is no longer possible, if the product:

 - shows visible signs of damage, 
 - no longer functions properly, 
 - has been stored under adverse ambient conditions for an extended period of 

time or 

 - has been exposed to considerable strain during transport.

•  Please handle the product with care. The product can be damaged if crushed, 

struck or dropped, even from a low height.

•  If you have doubts about how to operate the device or its safety, consult a trained 

technician.

•  If you have any questions that are not answered in these operating instructions, 

please contact our technical customer service or another specialist.

Содержание 1601070

Страница 1: ...fgrund der Funktionsweise des einpoligen Spannungsprüfers kann es jedoch zu Problemen kommen Beachten Sie deshalb unbedingt das nächste Kapitel Bedie nung Bedienungsanleitung Einpoliger Spannungsprüfer Best Nr 1601070 Bestimmungsgemäße Verwendung Das Produkt dient zum Prüfen von Wechselspannungen im Bereich von 100 250 V AC mit einer Frequenz von 50 500 Hz Es darf nicht für andere Arbeiten verwend...

Страница 2: ...ßerdem durch einen zu hohen Übergangswider stand der Haut beeinträchtigt werden z B trockene Haut oder Hornhaut Die Höhe der Spannung wird nicht angezeigt In bestimmten Fällen kann die Glimmlampe aufleuchten obwohl keine Spannung anliegt verursacht durch z B statische Aufladung Eine Prüfung des Nullleiters N oder Schutzleiters PE ist nicht möglich Messungen an Steckdosen mit Kindersicherung sind p...

Страница 3: ...r the operation of the single pole voltage tester can cause problems It is therefore important to follow the instructions in the next chapter Operation Operating instructions Single pole voltage tester Item no 1601070 Intended use The product is designed to test AC voltages in the range of 100 250 V AC with a frequency of 50 500 Hz It is not intended for other applications For safety and approval ...

Страница 4: ... the contact resistance of the skin is too high e g dry skin or cornea The amount of voltage is not displayed Under certain circumstances the glow lamp may light up even if there is no volta ge caused by e g static charge It is not possible to test the neutral conductor N or protective conductor PE In principle it is not possible to measure sockets with child protection possible because the design...

Страница 5: ...ant passant à travers la résistance en série dans le détecteur de tension n est pas dangereux Cependant il suffit pour que la lampe néon s allume La fonctionnalité du détecteur de tension unipolaire peut cependant engendrer des problèmes C est pourquoi il faut respecter absolument le prochain chapitre Utili sation Mode d emploi Détecteur de tension unipolaire N de commande 1601070 Utilisation conf...

Страница 6: ...de contact de la peau trop élevée par ex peau sèche ou callosité Le degré de tension ne sera pas affiché Dans certains cas la lampe néon peut s allumer bien qu aucune tension ne soit présente causée par exemple par une tension statique trop élevée Il n est pas nécessaire de vérifier le conducteur neutre N ou le conducteur de protection PE Les mesures sur des prises de courant dotées d une sécurité...

Страница 7: ... ongevaarlijk Het is echter voldoende dat de glimlamp oplicht Op basis van de manier van werking van de enkelpolige spanningstester kan het echter problemen veroorzaken Het is daarom belangrijk om het volgende hoofdstuk Bediening in acht te nemen Gebruiksaanwijzing Enkelpolige spanningstester Bestelnr 1601070 Beoogd gebruik Het product dient om wisselstroomspanningen te testen in het bereik van 10...

Страница 8: ...ave kan bovendien beïnvloed worden door een te hoge contactweerstand van de huid bijv Droge huid of hoornvlies De hoeveelheid spanning wordt niet weergegeven In bepaalde gevallen kan de glimlamp oplichten ook al is er geen spanning inge schakeld veroorzaakt bijv door een statische lading Een test van de nulleider N of de beschermende geleider PE is niet mogelijk Metingen op contactdozen met kinder...

Отзывы: