Place the PIR Motion Detector indoors only. If possible, the recommended position is in the 

corner of a room so that the logical path of an intruder would cut across the fan detection 

pattern.  PIR  Motion  Detectors respond  more  effectively to  movement across  the device 

than to movement directly towards it. 

 

Mount the PIR Motion Detector at a height between 2 and 2.5m. At this height the PIR 

Motion Detector will have a maximum range of up to 12m with a field of view of 110 degree.   

 

Tilt the Motion Detector facing slightly downward toward open area of room (approx. 14° angle) 

 

If you have a pet, place the included Pet-Immune Sticker on the lowest portion of the screen 

 

Install a 9 volt alkaline

 

battery and refit the cover.   

 

IMPORTANT:

 Set the NORM/TEST switch to “NORM” mode for normal use (see diagram 

above middle). The default is set to “TEST” mode for positioning and testing purpose. 

 

IMPORTANT:

 When the battery is first connected to the PIR Motion detector a 2~3 minutes 

period must be allowed for “Warming up”.

 

 

NOTE: 

1. Avoid locating the detector facing a window or where it is exposed to or facing sunlight. 

2. Avoid locating the detector in areas which contain objects likely to produce a rapid change in 

temperature, such as central heating, ventilator, radiator. boiler, ducts etc. 

3. Avoid locating the detector in a position where it is subject to excessive vibration. 

4. Make sure the detection area is not obstructed by curtains, large furniture, plants which etc 

which may block the pattern of coverage. 

5. Avoid installing 2 PIR detectors in one room protecting the same coverage area. 

Control Panel Installation 

 

Follow the step-by-step instructions below in accordance with the diagram. Please note that it is 

best to centralize the Control Panel within the alarm site to achieve the best wireless range and 

functionality. If desired, the Control Panel can be mounted on a wall by utilizing standard screws and 

the screw slot on the back of the Control Panel along with the screw hole under the battery cover. 

 

1)

 

Open the battery cover. 

2)

 

Connect one end of the included telephone line into the LINE jack on the Control 

Panel, and the other end into a telephone jack on the wall. 

3)

 

Connect a telephone to the PHONE jack on the Control Panel. 

4)

 

Connect the ES-01 Wired Loud Siren with Strobe (optional accessory) according to 

wiring diagram shown in the figure below. 

5)

 

Connect the included Adaptor to the POWER jack on Control Panel, and plug into an 

electrical outlet. 

6)

 

Install 3 pieces of AA size 1.2 volt / 1300mA Ni-Mh Rechargeable Battery 

7)

 

Refit the battery cover and ensure the Tamper switch is pressed properly. 

 

 

 

*NOTE:

 Because the battery is protected by a Tamper Switch the Control Panel must be set to 

TEST Mode when mounting the Control Panel, replacing the rechargeable backup batteries or 
wiring the optional wired accessories,   

SIMPLE STEP-BY-STEP PROGRAMMING 

 
 

The following programming instructions will take you through the entire programming in a simple 

step-by-step  format.  All  programming  is  accomplished  by  utilizing  the  keypad  on  the  Control 

Panel, while confirmation  tones (or beeps) will  confirm that  the programming was correct  and 

entered,  or incorrect and not  entered. The confirmation  tones  are as follows,  unless otherwise 

specified: 

 

One long beep = Correct and entered 

Содержание RD-03

Страница 1: ...tents Section Page IMPORTANT PLEASE READ THIS SECTION FIRST 2 Features Functions Benefits 3 Main Components Optional Accessories 5 Planning Your Installation 6 Easy Do It Yourself Installation 7 Simple Step by Step Programming 11 User Guide for Easy Operation 16 Advanced Programming 21 Wiring Diagrams 23 Your Questions Answered 25 ...

Страница 2: ...amage to property or other loss whether direct indirect incidental consequential or otherwise based on a claim that the Product failed to function FEATURES FUNCTIONS BENEFITS Do It Yourself Wireless System No hard wired installation necessary Practically effortless screw in or double sided tape mounting Up to 300 ft range covers entire house apartment small business etc Easy Setup Operation Simple...

Страница 3: ...ry Change mode Any attempt to remove the covers will activate an alarm Memory Chip Stores All Programmed Data EEPROM retains all programmed settings for each User Function even during power outages Completely Expandable Customizable Add any number of Wireless Sensors Detectors to each zone The expansion connector on control panel allows you to connect to an external siren strobe unit etc MAIN COMP...

Страница 4: ...mber of detectors to each zone Detectors sensors set to Zone 2 Zone 3 will not activate the system when set into Partial Arming At Home Mode As an example this is ideal for use in Bedrooms and a Hallway so that the system may be entered into Home Mode during the night thus allowing the occupants access to the upper rooms only NOTE It s very import to install the alarm panel in the center of a hous...

Страница 5: ...Sensor one Magnetic Contact and the included screws or double sided tape for each Door Window Sensor setup The Magnetic Contact and Transmitter must be line up as shown in the figure above Magnetic Contact should have a gap between 1 inch Check the Site Code and Zone Code is correct Install a 12 volt 23A Alkaline battery Model MT 01 Mount each MT 01 Wireless Door Window Sensor using the included s...

Страница 6: ...one room protecting the same coverage area Control Panel Installation Follow the step by step instructions below in accordance with the diagram Please note that it is best to centralize the Control Panel within the alarm site to achieve the best wireless range and functionality If desired the Control Panel can be mounted on a wall by utilizing standard screws and the screw slot on the back of the ...

Страница 7: ...ilar you can add a pause to the phone number by entering Ý within the number For example 9 12125551212 would dial 9 then pause for 2 seconds then dial 1 the area code and number 6 Within a few seconds you will hear a confirmation tone and the information is stored One long beep correct entry Three quick beeps incorrect entry must be re entered The LED will flash the programmed phone number for con...

Страница 8: ...ct entry Three quick beeps incorrect entry must be re entered Step 8 Ring Back Tone Learning This function allows the Control Panel to learn the unique telephone ring back specific to user s country or locale This is a very simple procedure but it is extremely important to the entire operation of the Auto Dialer feature 1 Make sure that a telephone number has been programmed into phone number posi...

Страница 9: ... procedures Some functions can be operated utilizing the Remote Control keypad on the Control Panel or from anywhere in the world via the Remote Call In feature which allows users to operate the system from any telephone The following operating instructions willhelp you to fully benefit fromthe many features and functions of the WIRELESS ALARM SYSTEM Enter Full Arming Away Mode This function is us...

Страница 10: ... time 6 The Control Panel will emit beep sounds as each detector is activated to confirm proper operation The number of beeps indicates the corresponding Zone of the sensor detector NOTE A doorbell sound indicates a low battery in the sensor detector This function is also useful to identify which of the sensors set to the same zone has a low battery To Exit Test Mode and enter Disarming Mode using...

Страница 11: ...hen system is in Partial Arming Mode LED off when system is in Disarming Mode Flashes once per 2 seconds when system is in Testing Mode Steady light with warning beeps when systemwas activated when last set to Arming mode Alarm Situations System Notifications The following table represents the various types of alarm situations and system notifications as well as the probable cause for each Alarm S...

Страница 12: ...lowing the procedure in Step 7 Code Learning from Remote Control in the Simple Step by Step Programming section Setting the Sensors Transmitters to Specific Zones This system has Six Zones plus a Panic Tamper Zone each of which can be triggered during various alarm situations see Active Zones below These Zones can help you to pinpoint which sensor transmitter was triggered in an alarm situation or...

Страница 13: ...Battery Check Not Active Not Active Not Active Not Active Not Active Not Active Not Active WIRING DIAGRAMS ...

Страница 14: ...cover removed Please ensure the cover is fully in place 3 Why do my batteries only last a few months in the PIR Motion Detector Check the battery connections are tight especially if you are using duracell as this make of battery has an unusually narrow positive nipple Make sure you have not left the switch in the PIR set to TEST mode 4 What is the Walk Through function and how to use it Asensor se...

Отзывы: