Toky AI208 Series Скачать руководство пользователя страница 3

K

J

E

PT100

CU50

CU100

0~50mV

4~20mA

0~10V

0~400Ω

-50~999

-50~400

-200~600

-50~150

-50~150

-199~999

-199~999

-199~999

-199~999

0~999

0~850

T

1℃

1℃

1℃

1℃

1℃

1℃

1℃

12bit

12bit

12bit

12bit

0.5%F.S±3digits

0.5%F.S±3digits

0.5%F.S±3digits

0.5%F.S±3digits

0.5%F.S±3digits

0.5%F.S±3digits

0.5%F.S±3digits

0.5%F.S±3digits

0.5%F.S±2℃

 0.5%F.S±3℃

0.5%F.S±1℃

>500kΩ

>500kΩ

>500kΩ

>500kΩ

0.2mA

0.2mA

0.2mA

>500kΩ

100Ω

>1MΩ

0.2mA

0

1

2

3

4

5

6

7

8

9

10

 

(Ⅰ)

control output

 

 Power Supply

SET

R/S 

3/10 page                                                                     KKAI208C01A-A1-20140904

*
*

4

1

2

3

6

5

7

OUT1

SV

PV

OUT2 AL1 AL2 AL3 AT

AT

INTELLIGENTIZED   METER

Shell material
Panel material

Power-off data protection
Protection level of panel

Safety Standard

The shell and panel frame PC/ABS (Flame Class UL94V-0)
PET(F150/F200)
10 years

times of writing:100w times

IP65(IEC60529)

IEC61010-1  Overvoltage category 

Ⅱ,

pollution level 2

level

Ⅱ(

Enhanced insulation

2

measured signal specifications

Input type

Measuring range

symbol

Resolution

Accuracy

Input impedance/

auxiliary current

Code

3

Isolation diagram

Please note when you choose the model

MCU

(Ⅱ)

measure input

 Relay

alarm output

Analog output

communication port 

( I ) auxiliar power

“    ”

Isolation

  Note: when there is no analog output,communication port between (

)and(

),part of specification(such as relay output) is isolation;

            SSR output is no isolation.

Name of universal panel

R/S 

Menu key/ensure key,to use enter or back to modified mode or ensure/save parameters

Add key/R/S

Display window (green)  Setting value/parameters display window,display “STP” =stop control

Display window (red)  measured value/parameters code display window

Reduce key

Add key,long press it can reach switch of RUN/STOP mode under the measure control mode. 

Reduce key

Activation key/shift key/AT setting key,long press to enter or back to auto-tuning 

under the measure control mode.

No.      symbol                Name                                                      Function

1

2

AL1
AL2
AL3

Alarm1# indicator light(red)
Alarm2# indicator light(red)

Alarm3# indicator light

3

AT indicator light(green)

Shift/AT key

SET function key

OUT1

OUT2

AT
SET

SV
PV

5

4

7

6

OUT2 indicator light(red)

OUT1 indicator light(red)

AT

Host control output indicator light,it light when the output is 0N
Cooling output indicator light,it light when the output is 0N
1st loop alarm output indicator light,alarm output with light,no alarm output without light.

2nd loop alarm output indicator light,alarm output with light,no alarm output without light.

AL3

This product has no the function

Auto-tuning indicator light,it show setting state when it light

Содержание AI208 Series

Страница 1: ...ault 10 Please tighten screw torque according to the rules If not it may lead to electric shock and fire 11 In order not to interfere with this products to dissipate heat please don t plug casing arou...

Страница 2: ...ted pair with a shield for remote RS485 communication cable and deal with the shield on the host side earth otherwise it will reduce the effect of noise filter 8 This product is not the fuse please se...

Страница 3: ...solation Note when there is no analog output communication port between and part of specification such as relay output is isolation SSR output is no isolation Name of universal panel R S Menu key ensu...

Страница 4: ...de and after power on long press SET key more than 3s to enter the menu parameters to ckeck the type b In the checking mode in menu you can press SET each short time to check the manu parameters recur...

Страница 5: ...nalog range low limit Analog range high limit note the value is reverse analog output when it less than analog range low limit Output low limit limit the output low limit current amplitude Setting val...

Страница 6: ...ose the function Temperature unit F Line signal input unit engineering work Digits User auto calibrating enable function this parameter is only for use of input signal expect TC RTD Y user of enable a...

Страница 7: ...normal room temperature please back to monitoring mode or input the load power and long press AT enter auto tuning mode now AT indicator will shine 7 Auto tuning will take the time in order not to af...

Страница 8: ...2 dyte seizes 2 data register The memory code of decimal integer 200 is 0x00C8 Note It should read DP value or ensure DP value in first to ensure the decimal point when reading data and need to transf...

Страница 9: ...ponse Write multi register CRC low CRC high Data high MeterADD StartADD Highbit StartADD Lowbit Databyte Length highbit Data byte Length high bit Databyte length FunctionID Data low CRCcode lowbit CRC...

Страница 10: ...DD ADD Communication baud rate BAD Communication relay setting DTC Optional input signal INP 1st loop alarm type AD1 2nd loop alarm type AD2 D7 D6 D5 D4 D3 D2 D1 D0 AT AL2 AL1 OUT2 OUT1 R Read R W Rea...

Отзывы: