WARNING
;
Do not touch the hoist after operation.
・
After operating the hoist, do not touch the hoist. After operation, the hoist may become hot. Please
let the hoist cool before touching.
WARNING
;
Do not use the limiter to stop the hoist all the time.
・
This mechanism is a safety device. The limiter for over lifting and over lowering will operate
continuously using this device may lead to an accident and it is not recommended to use it
continuously.
WARNING
;
Do not over look the load limiter setting and confirm before
using the hoist.
・
A load limiter is equipped within the hoist but please understand that this device is the final
emergency measure to stop the hoist. During actual operation, it is necessary that the load is
within the rated load of the hoist before it is used.
WARNING
;
The load limiter must be adjusted when the air pressure
changes.
・
The load limiter needs to be adjusted according to the air pressure being used. At the factory it
has been set at 125% of the rated load at 0.6 MPa. If the hoist will be used above this air pressure,
referring to the section of “ how to adjust the load limiter “ must be refereed. Also, depending on
the piping and hose size and length the setting may change. If the setting adjustment is not made
the hoist may stop below the rated capacity. It is dangerous to perform lifting of a load above 125%
of the rated load.
WARNING
;
Use one hoist when lifting.
・
When lifting for more than 2 hoists, balance becomes a factor and one hoist may be stronger and
this type of operation can become dangerous.