![Tohnichi TDT3-G Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/tohnichi/tdt3-g/tdt3-g_operating-instruction_1124791013.webp)
12
n
D
IG
IT
A
L
T
O
R
Q
U
E
S
C
R
E
W
D
R
IV
E
R
T
E
S
T
E
R
M
O
D
E
L
T
D
T
3
-G
5-9. Over-Torque Alarm
If applied torque exceeds 110% of the maximum limit of the measurable torque range, the value
on the display flashes for alarming.
5-10. Error Display
TDT3-G includes self-check function, and Err1-9 will be displayed when there is an error.
<<when Err1-5 appears>>
• Turn off the power, and turn it on without touching any keys.
· If Err disappears, it is restored.
· If Err continues to stay, contact your nearest distributor or TOHNICHI to seek assistance.
<<when Err8 appears>>
• Contact your nearest distributor or TOHNICHI for repair.
<<when Err9 appears>>
• Push C key at no load condition.
· If Err9 disappears, it is restored.
• If Err9 continues to stay, turn off the power once and turn it on again.
· If Err9 still continues to stay, contact your nearest distributor or TOHNICHI for repair.