6
- Tightening torque (setting):
This is the tightening torque value to set at the torque
tightening stage in the production tightening mode. After passing this torque, the
operator will be informed by the blue LED and the buzzer. When it goes over the
upper limit, the red LED lights up and another buzzer goes off to alarm the operator.
- Tightening angle (setting):
Tightening angle to set in the single-spindle tightening
mode. After passing the snug torque, angle counting starts. Upon reaching the set
angle, the blue LED lights up and the buzzer goes off. When it goes over the upper
limit, the red LED turns on and another buzzer goes off to alarm the operator.
- 1
st
(2
nd
, 3
rd
) tightening angle (setting):
Tightening angles to be set at each angle
tightening stage in production tightening mode. After passing the snug torque, angle
counting starts. When it passes the 1
st
torque (2
nd
torque, 3
rd
torque), the blue LED
turns on the buzzer goes off. When it goes over the upper limit value, the red LED
turns on and another buzzer goes off to alarm the operator.
- Number of bolts (setting):
It is the number of bolts to set in the production
tightening mode.
- Memory counter:
It is the counting number of the measured data. In the
single-spindle tightening mode, the counting number goes up each time it saves 1
bolt tightening data. In the production tightening mode, the counting number goes
up each time 1 cycle of tightening stages completes.
- Spindle counter:
In the production tightening mode, this counter goes up each time
tightening of 1 spindle completes. After completing the set number of bolts, it resets