![Tohnichi CTA2-G Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/tohnichi/cta2-g/cta2-g_instruction-manual_1124735038.webp)
37
●
Setting measurement unit (Default: N
・
m)
Select the torque unit
(
N
・
m
/
kgf
・
cm
/
kgf
・
m
/
lbf
・
in
/
lbf
・
ft
)
The measured torque and the set torque will be converted into the selected torque unit.
Use ▲▼key to
select the torque unit and press MEM key to save and proceed to the next.
(If you press MD key, it proceeds without saving. If you press C key, it returns to RUN
measurement mode).
●
Tightening torque setting (Default: 0)
Set the torque value of the torque tightening stage.
Use key to select the digit, and key to change the value. Press MEM key to confirm
and proceed to the next.
(Press MD to proceed without saving. Press C key to return to RUN measuring mode).
●
Tightening torque upper limit setting (Default: 0)
Set the tightening torque upper limit.
Use key to select the digit, and key to change the value. Press MEM key to confirm
and proceed to the next.
(Press MD to proceed without saving. Press C key to return to RUN measuring mode).
Select the torque unit
(N
・
m / kgf
・
cm / kgf
・
m / lbf
・
in / lbf
・
ft)
*Unit conversion is made based on N
・
m values with the above conversion factors.
*All the memory and torque setting values are converted when making a unit change.
Rounding of the converted figures
100.0[N
・
m] x 0.73756 = 73.756
≒
73.8[lbf
・
ft]
73.8[lbf
・
ft] ÷ 0.73756 = 100.05
≒
100.1[N
・
m]
*Converted figures are rounded as above.
Accordingly, the resulted figures may have a margin of errors