2. Setting by key operation on CTA2-G.
●
RUN mode
Press MD key for more than 2 sec. After the display changes to tightening mode setting,
release the key.
* If it is in production tightening mode, you must press the reset switch or unplug/plug the
recharging terminal to set it to RUN measuring mode.
* In single-spindle tightening mode, use key to set the counter to 000 for RUN mode.
●
Tightening mode setting
(
Default: MODE-S
)
Select the tightening mode.
MODE-S: Single-spindle tightening, MODE-P: Production tightening
Single-spindle tightening: Set the snug torque and tightening angle to conduct the angle
method tightening from the snug torque to the set angle.
Production tightening: Set the snug torque, tightening torque, 1
st
, 2
nd
, and 3
rd
tightening
angle, and the number of spindles to conduct the angle method
tightening for a series of work on the registered conditions.
Use key to select the mode and press MEM key to confirm. After confirmation, the
display turns to Data Clear check (Press MD key to proceed without saving. Press C key to
return to RUN measuring mode).
●
Data Clear check
Press MEM to save the tightening mode and proceed to next. (Press C key to return to
tightening mode setting.)
* If you change the tightening mode, tightened data will be deleted. Transfer the necessary
data to PC or Printer in advance.