Operating the device
Note:
The torque for tightening the working voltage terminal block on the
device is 4.5 lb-in (0.51 Nm).
The torque for tightening the terminal block on the digital input of the device
is 3 lb-in (0.34 Nm).
Mount the terminal block for the supply voltage and the signal contact
using screws.
Enable the supply voltage.
2.6
Connecting data cables
Note:
In general, adhere to the following recommendations for data cable
connections in environments with high electrical interference levels:
Keep the length of the data cables as short as possible.
Use optical data cables for the data transmission between the buildings.
When using copper cables, provide a sufficient gap between the power
supply cables and the data cables. Ideally, install the cables in separate
cable channels.
Use shielded cables.
Note:
Verify that you connect only optical ports with the same optical trans-
mission properties with each other.
For further information see
“10/100 Mbit/s twisted pair port” on page 25
.
For further information see
“100 Mbit/s F/O port” on page 26
.
WARNING
ELECTRIC SHOCK
Connect only a supply voltage that corresponds to the type plate of your
device.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.