EMC and immunity
Note:
You will find detailed information on the certificates and declarations applying to your device in a separate over-
view.
See table 3 on page 21.
Stability
Standard applica-
tions
Navy applications Railway applica-
tions
Substation appli-
cations
IEC 60068-2-6, test Fc
Vibration
5 Hz ... 8.4 Hz with
0.14 in. (3.5 mm)
amplitude
2 Hz ... 13.2 Hz
with
0.04 in. (1 mm)
amplitude
—
2 Hz ... 9 Hz with
0.12 in. (3 mm)
amplitude
—
—
—
—
8.4 Hz ... 150 Hz
with 1 g
13.2 Hz ... 100 Hz
with 0.7 g
—
9 Hz ... 200 Hz
with 1 g
—
—
—
—
—
—
—
200 Hz ... 500 Hz
with 1.5 g
IEC 60068-2-27, test Ea
Shock
15 g at 11 ms
—
0.53 oz (10 g) at
11 ms
EMC interference emis-
sion
Standard applica-
tions
Navy applications Railway applica-
tions (trackside)
Substation appli-
cations
Radiated emission
EN 55022
Class A
Class A
Class A
Class A
FCC 47 CFR Part 15
Class A
Class A
Class A
Class A
EN 61000-6-4
Fulfilled
Fulfilled
Fulfilled
Fulfilled
Conducted emission
EN 55022
AC and DC supply connections
Class A
Class A
Class A
Class A
FCC 47 CFR Part 15
AC and DC supply connections
Class A
Class A
Class A
Class A
EN 61000-6-4
AC and DC supply connections
Fulfilled
Fulfilled
Fulfilled
Fulfilled